there is no fatal error, such as a problem with accessing Device Manager -
Storage Navigator.
•
Dump_Detail_bat
collects detailed dump files and contains comprehensive
information about the storage system in addition to the contents of the
normal dump file. Use this tool if you cannot start Device Manager -
Storage Navigator or to check for problems with the storage system.
Using the Dump tool
Before you begin
• The client PC must be connected to the SVP using the Remote Desktop
Connection.
• Verify Hitachi Device Manager - Storage Navigator is running.
• No other user should be using the Dump tool.
• No maintenance operation is being performed.
• Dump tools for other storage systems are not being used.
Note:
If there are issues related to starting Hitachi Device Manager - Storage
Navigator, use the dump tool while Hitachi Device Manager - Storage
Navigator is not running and collect the information related to SVP.
Procedure
1.
In Hitachi Device Manager - Storage Navigator, click
File > Refresh All
to refresh the configuration information shown.
2.
On the SVP, exit to a Windows command prompt as Administrator.
3.
Change to the directory where the Dump tool is located.
For example,
C:\Mapp\wk\83xxxxxxx\DKC200\mp\pc
where
83xxxxxxx
is
the DKC serial number.
Note:
In the command above,
C:\Mapp
indicates the installation
directory of the SVP. If the installation directory is different,
replace
C:\Mapp
with the specified installation directory.
4.
Specify the output folder for the dump file (for example,
C:\Mapp\wk
\83xxxxxxx\DKC200\tmp
) as an output destination, and then run
Dump_Normal.bat
or
Dump_Detail.bat
. For example, to output the
performance result of the Detail Dump tool to
C:\Result_832000400001
,
enter the following:
Dump_Detail.bat C:\Result_832000400001
Note:
The dump file name is
hdcp.tgz
. To manage the dump file
for each storage system, assign the serial number to the output
destination folder name. For example, If the serial number: is
832000400001
, set the file name to
C:\Result_832000400001
.
While executing the tool,
Executing
appears in the command
Troubleshooting the storage system
379
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...