9.
Alight the notch on the cache memory board with the projection inside
the slot.
10.
Holding both ends of the cache memory, insert it into the socket of the
new controller.
11.
Check that the lever is securing the cache memory.
12.
To install the DIMM cover, slide it in the direction of the arrow. Confirm
that the DIMM cover is secured by the two hooks on either side.
13.
Check that the connector of the controller is not damaged, deformed, or
dusty.
14.
With the right and left levers on the controller opened completely, insert
it into the slot of CBSS or CBSL controller.
15.
Push the controller in all the way. The right and left levers close
completely.
16.
Tighten the blue screw to secure the controller.
17.
Connect all cables removed from the controller.
18.
Confirm that the red
CTL ALM
LED on the controller in which the cache
memory was installed goes off.
Next steps
• Use the maintenance utility to restore (unblock) the controller.
Replacing cache memory for a CBLM or CBLH controller
When replacing cache memory on a CBLM or CBLH controller, remove the
backup module first, and then remove the controller. A single CBLM or CBLH
controller weighs approximately 42 pounds (19 kg).
Replacing cache memory
191
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...