Note:
If the
ALM
LED is ON but the drive status is neither
Blocked
nor
Failed
, contact the HDS Support Portal at
support.hds.com/en_us/contact-us.html
.
7.
In the maintenance utility, click
Hardware > Controller Chassis
Hardware > Drive Box
.
8.
Click the
Drives
tab.
9.
Confirm that the status of the drive to be replaced is
Normal
.
If necessary, click
Refresh
to update the status in the window.
10.
Confirm that the red
ALM
LED is off at the new drive.
11.
Attach the front bezel.
Replacing a drive for a flash module drive tray
The drive numbering is #0 to #11, from the bottom left to the top right.
Before you begin
• Wear a wrist strap connected to the storage system to prevent part
failures caused by static electricity. Do not remove the wrist strap until you
finish the procedure.
• Confirm that the storage system power is turned on.
• The front bezel is removed.
Note:
Servicing flash module drives is strictly limited to Hitachi and certified
partners. The flash module drive tray accepts DKC-F810I-1R6FN, DKC-
F810I-3R2FN, DKC-F810I-6R4FN, DKC-F810I-7R0FP or DKC-F810I-14RFP
drives only. HDDs cannot be installed in a flash module drive tray. You cannot
install small form factor drive trays, large form factor drive trays, and dense
intermix drive trays on an all-flash array.
Replacing a drive
115
Service Guide for VSP Gx00 and VSP Fx00 Models
Summary of Contents for Virtual Storage Platform F400
Page 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Page 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...