Output Terminal
Configuration
The inverter provides configuration for logic (discrete) and analog outputs, shown in the table
below.
NOTE:
*Terminals [11] – [13] or [11] – [14] are automatically configured as AC0 – AC2 or
AC0 – AC3 when C62 is configured to enable alarm code output.
The output logic convention is programmable for terminals [11] – [15], and the alarm relay
terminals. The open-collector output terminals [11] – [15] default to normally open (active
low), but you can select normally closed (active high) for the terminals in order to invert the
sense of the logic. You can invert the logical sense of the alarm relay output as well.
“C” Function
Run
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(EU)
–FU
(US)
–FR
(JP)
C021
Terminal [11] function *
22 programmable
functions available
for logic (discrete)
outputs (see next
section)
✘ ✔
01
[FA1]
01
[FA1]
01
[FA1]
—
>C021 OUT-TM
11 FA1
C022
Terminal [12] function *
✘ ✔
00
[RUN]
00
[RUN]
00
[RUN]
—
>C022 OUT-TM
12 RUN
C023
Terminal [13] function *
✘ ✔
03
[OL]
03
[OL]
03
[OL]
—
>C023 OUT-TM
13 OL
C024
Terminal [14] function *
✘ ✔
07
[OTQ]
07
[OTQ]
07
[OTQ]
—
>C024 OUT-TM
14 OTQ
C025
Terminal [15] function
✘ ✔
08
[IP]
08
[IP]
08
[IP]
—
>C025 OUT-TM
15 IP
C026
Alarm relay terminal
function
✘ ✔
05
[AL]
05
[AL]
05
[AL]
—
>C026 OUT-TM
AL AL
C027
[FM] signal selection
8 programmable
functions available
for analog outputs
(see after next
section)
✘ ✔
00
output
freq.
00
output
freq.
00
output
freq.
—
>C027 FM-MONITOR
KIND A-F
C028
[AM] signal selection
✘ ✔
00
output
freq.
00
output
freq.
00
output
freq.
—
>C028 AM-MONITOR
KIND A-F
C029
[AMI] signal selection
✘ ✔
00
output
freq.
00
output
freq.
00
output
freq.
—
>C029 AMI-MON
KIND A-F