background image

 

 

 

HD COLOR CAMERA SYSTEM

 

 

REMOTE

 

CONTROL UNIT

 

 RU-1500JY 

R1

 

 

 

OPERATING INSTRUCTIONS

 

 

 

 

Please read this operating instruction carefully for proper operation,   
and keep it for future reference.

 

 
 
 

 

 

Note: 

The model and serial numbers of your product are important for you to keep for your 

convenience and protection.    These numbers appear on the nameplate located on bottom of 

the product.  Please record these numbers in the spaces provided below, and retain this 

manual for future reference. 

 

Model No.                                         

       

            Serial No.

                           

 

Additional information 

Summary of Contents for RU-1500JY

Page 1: ...ep it for future reference Note The model and serial numbers of your product are important for you to keep for your convenience and protection These numbers appear on the nameplate located on bottom of the product Please record these numbers in the spaces provided below and retain this manual for future reference Model No Serial No Additional information ...

Page 2: ... 4 6 7 or CU HD1000 CU HD1000 12V Supply Control cable C 102RH L2 SW HUB LAN cable LAN cable Power cable C 101ET LAN cable The power of RU 1500 is supplied thorough the control cable Therefore the control cable should be connected to the CCU even on Ethernet connection The power cable C 101ET services the power of XLR4pin NOTE The version for CCU supporting Ethernet connection is CU HD1000 V 2 00 ...

Page 3: ...ing menu REMOTE SELECT Move to a menu that an address setting of the connected CCU This is the local address information Press CONFIG button to set the IP Address the Netmask and the Gateway But the TAKEN must be OFF To go back to previous page press the BACK button Note The MAC address is not be changed DISCONNECT DATE TIME PREV OTHERS LOCAL ADDRESS ETHERNET ON REMOTE SELECT Item Setting RU 1500 ...

Page 4: ...e to previous page CANCEL Cancel the new setting and then move to previous page Item Setting RU 1500 Initialize Description SET Store the new setting and then move to previous page CANCEL Cancel the new setting and then move to previous page Item Setting RU 1500 Initialize Description Select No 1 128 Select number by the Rotary encoder1 see Note CONNECT ON Yellow OFF Gray ON Yellow Connecting to t...

Page 5: ...nnection message will be displayed to press the CONNECT button at CONNECT ON YES Disconnected from the network NO Connecting to the network is continued A fail message will be displayed at fail to connect Press OK button then go back to previous page A connection message will be displayed to press the CONNECT button at CONNECT OFF YES Connected to the network NO Quit to connect ...

Page 6: ...DATE TIME PREV OTHERS S e l e c t N o 1 SET CANCEL IP Address 172 16 1 1 Set the IP address to connect by Rotary encoder 1 to 4 Item Setting RU 1500 Initialize Description SET Store the new setting and then move to previous page CANCEL Cancel the new setting and then move to previous page ...