background image

RAS-S30CPZ

Instruction manual

Page 1~22

To obtain the best performance and ensure years of
trouble free use, please read this instruction manual
completely.

تﺎﻤﻴﻠﻌﺘﻟا ﺐﻴﺘﻛ

٢٢-١ ص             

ﻮـﻃ ةﺪﳌ زﺎﻬﳉا لﺎﻤﻌﺘﺳا ﻦﻜﳝ ﻲﻜﻟ

عﻼﻃﻹا ﺐﺠﻳ ﺐﻄﻋ نوﺪﺑ ﺔﻠﻳ

.اﺪﻴﺟ ﺐﻴﺘﻜﻟا اﺬﻫ ﻰﻠﻋ

RAC-S30CPZ

SPLIT TYPE

INDOOR UNIT/OUTDOOR UNIT

MODEL

RAS-S30CPZ/RAC-S30CPZ

INDOOR UNIT

OUTDOOR UNIT

<

H224: A 

>

Made in Malaysia

Summary of Contents for RAC-S30CPZ

Page 1: ...s of trouble free use please read this instruction manual completely اﻟﺘﻌﻠﻴﻤﺎت ﻛﺘﻴﺐ ٢٢ ١ ص ﻃـﻮ ﳌﺪة اﳉﻬﺎز اﺳﺘﻌﻤﺎل ﳝﻜﻦ ﻟﻜﻲ اﻹﻃﻼع ﻳﺠﺐ ﻋﻄﺐ ﺑﺪون ﻳﻠﺔ ﺟﻴﺪا اﻟﻜﺘﻴﺐ ﻫﺬا ﻋﻠﻰ RAC S30CPZ SPLIT TYPE INDOOR UNIT OUTDOOR UNIT MODEL RAS S30CPZ RAC S30CPZ INDOOR UNIT OUTDOOR UNIT H224 A Made in Malaysia ...

Page 2: ... where there is flammable gas The outdoor unit may catch fire if flammable gas leaks around it Please ensure smooth flow of water when installing the drain hose CAUTION PRECAUTIONS DURING SHIFTING OR MAINTENANCE PRECAUTIONS DURING OPERATION Avoid an extended period of direct air flow for your health W A R N I N G Should abnormal situation arises like burning smell please stop operating the unit an...

Page 3: ... water will condense on the air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved Do not climb on the outdoor ...

Page 4: ...unit Refer page 18 FRONT PANEL AIR INLET INDOOR UNIT INDICATORS Light indicator showing the operating condition Refer page 5 HORIZONTAL DEFLECTOR VERTICAL DEFLECTOR AIR OUTLET Refer page 13 REMOTE CONTROLLER Send out operation signal to the indoor unit So as to operate the whole unit Refer page 6 DRAIN PIPE Condensed water drain to outside CONNECTING CORD AND INSULATION PIPE FOR PIPING AIR INLET B...

Page 5: ...en the operation is done using the temporary switch after the power source is turned off and turn on again the operation is done in automatic mode OPERATION INDICATOR TIMER LAMP This lamp lights when the timer is working OPERATION LAMP This lamp lights during operation FILTER LAMP When the device is operated for a total of about 200 hours the FILTER lamp lights to indicate that it is time to clean...

Page 6: ...s this button to stop operation only SUPER SILENT button Use this button to set silent condition FAN SPEED selector This determines the fan speed Every time you press this button the intensity of circulation will change from AUTO to HI to MED to LOW AUTO SWING button Controls the angle of the horizontal air deflector TEMPERATURE button Use this button to raise or lower the temperature setting Keep...

Page 7: ...SPEED button the display indicates the setting AUTO The FAN SPEED is HI at first and varies to MED or LOW automatically when the preset temperature has been reached HI Economical as the room will become cool quickly MED Fan speed slow LOW Fan speed slower Set the desired room temperature with the TEMPERATURE button the display indicates the setting The range of 25 28 C is recommended as the room t...

Page 8: ... current room temperature regardless of the temperature setting The function will stop the indoor unit will stop emitting air as soon as the room temperature becomes lower than the setting temperature As the settings are stored in memory in the remote controller you only have to press the DEHUMIDIFY button next time Set the desired room temperature with the TEMPERATURE button the display indicates...

Page 9: ...etting fan speed and timer value on remote controller will remain no change 1 CANCELLATION of SUPER SILENT Operation Cancel Condition Operation mode after cancel Press button Sleeping timer time is up Stop operation Press button Next fan speed operation NOTE Under SUPER SILENT operation and quiet environment phenomena like flowing noise of refrigerant in the refrigerating cycle may occur but this ...

Page 10: ...ol button to set to the desired temperature As the settings are stored in memory in the remote controller you only have to press the CIRCULATION button next time 1 3 Press the STOP button to stop operation STOP 2 Circulation Function During circulation operation compressor will not be running and there is no cooling operation with only indoor fan running When the setting temperature is higher than...

Page 11: ...formation will be displayed on the remote controller The TIMER lamp lights with a beep from the indoor unit SLEEP 4 Indication 1 hr 2 hrs 3 hrs 10 hrs 11 hrs 12 hrs Sleep timer off 4 4 Explanation of the sleep timer The device will control the FAN SPEED and room temperature automatically so as to be quiet and good for people s health You can not set other timer during sleep timer operation After s...

Page 12: ...e will change according to the below sequence ON Timer Reservation 1 2 3 9 10 11 12 1 hour interval CANCEL OFF TIMER Operation will start for setting temperature at setting time Unit will be ON at pre set duration However unit might be ON at earlier depend on the room temperature and set temperature ...

Page 13: ...ep the horizontal air deflector swinging for a long time Some dew may form on the horizontal air deflector and dew may drop Adjustment of the conditioned air in the upward and downward directions The horizontal air deflector is automatically set to the proper angle suitable for each operation The deflector can be swung up and down continuously and also set to the desired angle using the AUTO SWING...

Page 14: ...different kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 or 3 months 3 Use high quality and high performance AAA batteries to avoid short operating life and electrolyte leakages CAUTION When using the remote control if there is no response from the air conditioner unit and or the remote control has fading and dim displays the batteries in the r...

Page 15: ...timer operation mode together with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty air filter will reduce the air volume and the cooling efficiency To prevent from wasting electric energy please clean the filter every 2 weeks Please pay attention to the room temperature and air flow direction when operating the un...

Page 16: ...e used for a long period of time please switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 8W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket OFF Interference From Electrical Products Inverter type fluorescent lamp...

Page 17: ...carried out only by qualified service personal Before cleaning stop operation and switch off the power supply CAUTION CAUTION Do not bend the air cleansing filter as it may cause damage to the structure NOTE In case of removing the air cleansing filters please follow the above procedures The cooling capacity is slightly weakened and the cooling speed becomes slower when the air cleansing filters a...

Page 18: ... it with soft bristle brush Allow filters to dry in shade 3 Re insert the air cleansing filter to the filter frame Set the filter with FRONT mark facing front and slot them into the original state After attaching the filters push the front panel at three arrow portions as shown in figure and close it CAUTION Do not wash with hot water at more than 40 C The filter may shrink When washing it shake o...

Page 19: ...dy of the unit when cleaning it as this may cause short circuit Never use hot water above 40 C benzine gasoline acid thinner or a brush because they will damage the plastic surface and the coating Removing the Front Panel When the front panel is fully opened with both hands push the right arm to the inside to release it and while closing the front panel slightly put it out forward Attaching the Fr...

Page 20: ... contact between them Cleaning and maintenance must be carried out only by qualified service personal Before cleaning stop operation and switch off the power supply CAUTION Confirm Note If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 3 MAINTENANCE AT BEGINNING OF LONG OFF PERIOD Run the unit by settin...

Page 21: ...lowing noise of refrigerant in the refrigerating cycle 2 Slight rubbing noise from the fan casing which is cooled and then gradually warmed as operation stops The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the air filter and the evaporator regularly must be cleaned to reduce the odor Please co...

Page 22: ...of the local Power Supply Companies are to be observed Minimum Maximum Indoor Dry bulb C 21 32 Wet bulb C 15 23 Outdoor Dry bulb C 21 52 Wet bulb C 15 31 Note Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21 C 70 F The recommended maximum and minimum operating temperatures of the hot and cold sides should be as below Cooling ...