HITACHI SPLIT-UNIT AIR CONDITIONER 

INSTALLATION MANUAL

  +  –  Screwdriver   

 Measuring Tape   

 Knife

 Saw  

 ø 65mm Power Drill 

 Allen Key (      4mm)

 Wrench (14, 17, 19, 22mm)

 Gas Leakage Detector    

 Pipe Cutter

 Plastic Tape    

 Pliers    

 Flare Tool

 Carefully read through the procedures of proper 

installation before starting installation work.

  The sales agent should inform customers regarding 

the correct operation of installation.

Tools Needed For Installation Work

SAFETY PRECAUTION

  Read the safety precautions carefully before operating the unit.

  The contents of this section are vital to ensure safety. Please pay special attention to the following sign.

  

WARNING ........ Incorrect methods of installation may cause death or serious injury.

  

CAUTION ......... Improper installation may result in serious consequence.

  Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of 

operating the unit as described in the user’s guide.

WARNING

CAUTION

  Be sure to use the earth line. Do not place earth line near gas or water pipes, lightning conductor

 

and the earth line of telephone. Improper earthing may cause electric shocks.

  A circuit breaker should be installed depending on the mounting size of the unit. Without a circuit breaker, the 

danger of electric shock exists.

  Do not install the unit near a location where there is  ammable gas. The outdoor unit may

 

catch  re if  ammable gas leaks around it.

  Please ensure smooth  ow of water when installing the drain hose.

  Please request your sales agent or quali ed technician to install your unit. Water leakage, short circuit or  re 

may occur if you do the installation work yourself.

  Please observe the instructions stated in the installation manual during the process of installation. Improper 

installation may cause water leakage, electric shock and  re.

  Make sure that the units are mounted at locations which are able to provide full support to the weight of the 

units. If not, the units may collapse and impose danger.

  Observe the rules and regulations of the electrical installation and the methods described in the installation 

manual when dealing with the electrical work. Use wire which is speci ed for the air conditioner. A short circuit 
and  re may occur due to the use of low quality wire or improper work.

  Be sure to use the speci ed wire for connecting the indoor and outdoor units. Please ensure that the connections 

are tight after the conductors of the wire are inserted into the terminals. Improper insertion and loose contact 
may cause over-heating and  re.

  Please use the speci ed components for installation work. Otherwise, the units may collapse or water leakage, 

electric shock and  re may occur.

  Do not mix any coolant other than R-22 into the cooling circulation path when mounting or shifting the unit. If it 

is mixed with air, the high pressure in the circulation path will rise and this may result in broken copper pipes 
or faults.

THE CHOICE OF MOUNTING SITE 

 (Please note the following matters and obtain permission from customer before installation).

WARNING

 The unit should be mounted at stable, non-vibratory location 

which can provide full support to the unit.

WARNING

  The outdoor unit must be mounted at a location which can support 

heavy weight. Otherwise, noise and vibration will increase.

CAUTION

 No nearby heat source and no obstruction near the air outlet is 

allowed.

 The clearance distances from top, right and left are speci ed in 

 gure  below.

 The location must be convenient for water drainage and pipe 

connection with the Outdoor unit.

 To avoid interference from noise please place the unit and its 

remote controller at least 1m from the radio, television and inverter 
type  uorescent lamp.

  To avoid any error in signal transmission from the remote controller, 

please put the controller far away from high-frequency machines 
and high-power wireless systems.

 The installation height of indoor unit must be 2.3m or more in a 

non public area. 

CAUTION

 Do not expose the unit under direct sunshine or rain. Besides, 

ventilation must be good and clear of obstruction.

  The air blown out of the unit should not point directly to animals 

or plants.

 The clearances of the unit from top, left, right and front are 

speci ed in  gure below. At least three of the above sides must 
be open air.

 Be sure that the hot air blown out of the unit and noise do not 

disturb the neighbourhood.

  Do not install at a location where there is  ammable gas, steam, 

oil and smoke.

 The location must be convenient for water drainage.

 Place the outdoor unit and its connection wire at least 1m away 

from the antenna or signal line of television, radio or telephone. 
This is to avoid noise interference.

INDOOR UNIT

Names of Indoor Components

The Length of Indoor Unit 

Power Cord

Do not alter the power cord.

Direction of Piping

Figure showing the Installation 
of Indoor and Outdoor Unit

 The difference in height 

between the indoor and 
outdoor unit should be 
kept max. 10m.

 The connecting pipe, 

no matter big or small, 
should all be insulated 
with insulation pipe and 
then wrapped with plastic 
tape. (The insulator will 
deteriorate if it is not 
wrapped with tape).

The connection of insulated 
drain hose.

Please use insulated drain 
hose for the indoor piping 
(commercial product).

OUTDOOR UNIT

Be sure to 
completely 
seal any 
gap with 
putty.

T h e r e   a r e   4   d i r e c t i o n s  
allowed, namely, horizontally 
perpendicular to the unit, 
vertically down from right, 
horizontally out from right and 
horizontally out to left.
Don't form the piping downward 
at the left of the unit.

<

IA667: B 

>

Screw for Remote 
Controller

( 3 . 5 x 1 8 )

AAA Size Battery

Mounting Plate

Qty

No.

Component’s Name

1

6

2

2

Remote Controller

!

Indoor Unit

Outdoor Unit

RAS-E10CZ

In case the pipe length is more than 8m, add refrigerant R22 at 
10 gram per every meter exceeds. However, pipe length shall 
not exceed 15m.

CAUTION

1

2

3

4

5

6

1

Installation of Hanger, Wall Penetration and Installation of Protection Pipe

1

CAUTION

 The draining of the water container inside the indoor unit can be done from the 

left. Therefore the hanger must be  xed horizontally or slightly tilted towards the 
side of drain hose. Otherwise, condensed water may over ow the water container.

Direct Mounting On The Wall

 Please use hidden beams in the wall to hold the hanger.

Wall Penetration and Installation of Protection Pipe

 Drill a ø 65mm hole on 

wall which is slightly tilted 
towards the outdoor side. 
Drill the wall at a small 
angle.

 Cut the protection pipe 

according to the wall 
thickness.

 Empty gap in the sleeve 

of protection pipe should 
be completely sealed with 
putty to avoid dripping of 
rain water into the room.

   Installation of the Indoor Unit

2

VERTICALLY DOWNWARD PIPING

 

 Preparation

 Connect connecting cord.

 Pull out the pipe, connecting cord and drain hose.

 

 Installation

 The upper part of the Indoor unit is hanged on the hanger.

 The projection at the lower part of the Indoor unit is hooked onto the hanger.

Please pull the lower part of 
the Indoor unit outwards to 
check if the unit is hooked 
onto the hanger. Improper 
i n s t a l l a t i o n   m a y   c a u s e 
vibration and noise.

!

CAUTION

HORIZONTAL PIPING

  Preparation

Change of Drain Hose and Installation Procedures.

  Exchange the location of drain hose and drain cap during horizontal piping as shown in 

 gure below. Be sure to plug in the drain hose until the insulating material folds upon itself.

 Please use pliers to pull out the drain cap.

  (This is an easier way to remove the drain cap).

INSTALLATION OF REFRIGERATING PIPES AFTER CONNECTION

 The refrigerating pipes should be adjusted to  t 

into the hole on the wall and then ready for further 
connection.

 The terminals of 2 connected pipes must be covered 

with insulator used for terminal connection. Then the 
pipes are wrapped with insulation pipe.

 Connect the connecting cord after removing electrical 

cover. (Refer to “CONNECTION OF POWER CORD”)

 After  adjustment,   t the connecting cord and pipes 

into the space available under the indoor unit. Use 
holder to hold them tight.

CAUTION

 The rubber strap used for 

 xing the insulator should 
not be tied with great force. 
Otherwise, this will damage 
heat insulation and causes 
water condensation.

 

Holder can be attached at the either of 2 places. 
Please select the easier position.

THE CONNECTION OF REFRIGERATING PIPE DURING THE 
INSTALLATION OF INDOOR UNIT

Preparation To Install Refrigerating Pipes

CAUTION

 Please  x in the plastic core 

after  aring to avoid plastic 
chips entering the pipes.

CAUTION

You are free to choose the side (left or right) for the installation of drain 
hose. Please ensure the smooth  ow of condensed water of the Indoor 
unit during installation. (Carelessness may result in water leakage.)

CAUTION

Be sure that the 
drain hose is not 
loosely connected 
or bend.

Be sure that the wire is not 
in contact with any metal 
in the wall. Please use 
the protection pipe as wire 
passing through the hollow 
part of the wall so as to 
prevent the possibility of 
damaged by mouse.
Unless it seals completely, 
any air with high humidity 
flows from outdoor and 
any dew may drop.

WARNING

 The refrigerating pipes and connecting cord 

transform and are attached.

 The end of the refrigerating pipes are at locations 

marked with “ 

   

 ” symbol.

   Installation of Drain Hose

3

  Installation

Hang the Indoor unit onto the hanger. Use the temporary 
stand at the back of the Indoor unit to push its lower part 
15cm forwards.

 Place the drain hose through the hole on the wall.

 Wrap the refrigerating pipes with insulation pipe after 

connecting refrigerating pipe.

  Connect the connecting cord after removing electrical cover. 

(Refer to “Connection of Power Cord”)

  After adjustment, the connecting cord and refrigerating pipes 

are placed into the space available under the Indoor unit.

 The projection of Indoor unit must hook to the hanger.

INDOOR UNIT

HOW TO REMOVE INDOOR UNIT

 Push up the (PUSH) sections at the 

bottom of the indoor unit and pull the 
bottom plate towards you. Then the 
claws are released from the stationary 
plate.

  (The (PUSH) sections are indicated 

by 2 arrows in the right  gure)

CAUTION

Condensed water may leak out if not inserted properly.

HORIZONTAL & DOWNWARD PIPING – MAKING OPENINGS

 During horizontal or downward piping, use a knife to cut 

openings as shown in  gure. Then smoothen the edges of 
openings with a  le.

 Turn the piping while holding down the lower 

portion of pipe-support by hand.

Heat insulation pipe

Refrigerating pipe

Pull this to the 
front during the 
connection of 
refrigerating pipes 
to ease task.

RAC-E10CZ

1

Holder

Dimension of Mounting Stand

of the Outdoor unit

Procedures of Installation and Precautions

 Procedures to  x the hanger.

1. Drill holes on wall. 

2. Push plug into the holes. 

3. Fix the hanger on wall

  (As shown below) 

  (As shown below) 

  with 4.1 x 32 screw

    

   

(As shown in  gure  below)

 Procedures to  x the holder of remote control.

1. Drill holes on wall. 

2. Push plug into the holes.

  (As shown below) 

  (As shown below)

Connecting
cord

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

INS RAS-E10CZ (EN1)   1