Names of Outdoor Components

No.

Item

Qty

Drain Pipe

s

The refrigerating machine oil is
easily affected by moisture. Use
caution to prevent water from
entering the cycle.

s

The difference in height between
the indoor and outdoor unit
should be kept below 10m.

s

The connecting pipe, no matter
big or small, should all be
insulated with insulation pipe and
then wrapped with vinyl tape.
(The insulator will deteriorate if
it is not wrapped with tape).

The connection of insulated 
drain hose.
          Inner diameter 16mm

Please use insulated drain

 hose for the indoor piping 

(commercial product)

 

give clearance as wide as possible

Maximum pipe length 20m

Minimum pipe length 3m

 50mm

above 200mm

 300mm

(10)

10

500

660

750

500

50

792

500

340

320

10

12
39

146

34

12

29

7

80

317

above 

above 

1

1

1

2

2

1

2

1

1

The Outdoor unit must be mounted at a location which can support heavy 
weight. Otherwise, noise and vibration will increase.

s

s

The air blown out of the unit should not point directly to animals  or plants.

s

The clearances of the unit from top, left, right and front are specified in figure 
below . At least  three  of the above  sides must be  open air .

s

Be sure that the hot air blown out of the unit and noise do not disturb the 
neighbourhood.

s

Do not install at a location where there is flammable  gas,steam, oil and smoke.

s

The location must be convenient  for water drainage.

s

Place the Outdoor unit and its connecting cord at least 1 m away from the antenna 
or signal line of television, radio or telephone. This is to avoid noise interference.

A circuit breaker  must be installed  in the house distribution box  for the direct 
connected power supply cables to the outdoor unit. In case of other installations 
a main switch with a contact  gap or more than 3mm has to be installed.
Without a circuit breaker, the danger of electric shock exists.

Do not install the unit near a location where there is flammable gas. 
The outdoor unit may catch fire if flammable gas leaks around it.

Please ensure  smooth flow of water when installing the drain hose. Improper 
installing may wet your furniture.

An IEC approved power cord should be used. Power cord type: NYM.

 WARNING

s

 CAUTION

 CAUTION

s

s

s

s

THE CHOICE OF MOUNTING SITE

 

(Please note the following matters and obtain permission from customer  before installation.)

FOR   SERVICE   PERSONNEL   ONLY

SAFETY PRECAUTION

s

Read the safety precautions carefully before operating the unit.

s

The contents of this section are vital to ensure safety. Please pay special attention to the following sign.

    WARNING

.......... Incorrect methods of installation may cause death or serious injury.

    CAUTION

.......... Improper installation may result in serious consequence.

    Make sure to connect earth line.
    This sign in the figures indicates prohibition.

Be sure that the unit operates in proper condition after installation. Explain to customer the proper operation and maintenance of
the unit as described in the user' s guide. Ask a customer to keep this installation manual together with the instruction manual.

  WARNING

s

Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you do the
installation work yourself.

s

Please observe the installation stated in the installation manual during the process of installation. Improper installation may cause
water leakage, electric shock and fire.

s

Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may
collapse and impose danger.

s

Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing
with the electrical work. Use cables which are approved official in your country. Be sure to use the specified circuit. A short circuit and
fire may occur due to the use of low quality wire or improper work.

s

Be sure to use the specified cables for connecting the indoor and outdoor units. Please ensure that the connections are tight after the
conductors of the wire are inserted into the terminals to prevent the external force is being applied to the connection section of the
terminal base. Improper insertion and loose contact may cause over-heating and fire.

s

Please use the specified components for installation work. Otherwise, the unit may collapse or water leakage, electric shock, fire or
stronger vibration may occur.

s

Be sure to use the specified piping set for R410A. Otherwise, this may result in broken copper pipes or faults.

s

When installing or transferring an air conditioner to another location, make sure that air other than the specified refrigerant (R410A)
does not enter the refrigeration cycle. If other air should enter, the pressure level of the refrigeration cycle may increase abnormally
which could result in a rupture and injury.

s

Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with fire, a poisonous gas may
occur.

s

After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks into the
room, coming into contact with fire in the fan-driven heater, space heater, etc., a poisonous gas may occur.

s

Unauthorized modifications to the air conditioner may be dangerous. If a breakdown occurs please call a qualified air conditioner
technician or electrician. Improper repairs may result in water leakage, electric shock and fire, etc.

s

Be sure to connect the earth line from the power supply wire to the outdoor unit and between
the outdoor and indoor unit. Do not connect the earth line to the gas tube, water pipe, lighting rod or the earth line of the
telephone unit. Improper earthing may cause electric shocks.

s

When finishing the refrigerant collection (pumping down), stop the compressor and then remove the coolant pipe.
If you remove the refrigerant pipe while the compressor is operating and the service valve is released, air is sucked and a
pressure in the freezing cycle system will build up steeply, causing an explosion or injury.

s

When installing the unit, be sure to install the refrigerant pipe before starting the compressor.
If the refrigerant pipe is not installed and the compressor is operated with the service valve released, air is sucked and the
pressure level of the refrigeration cycle may increase abnormally which could result in a rupture and injury.

The electric cables should neither be reworked nor  added.
Make sure to use an exclusive circuit breaker.
Otherwise fire or electric shock might occur by connection failure, isolation failure or over current. 
Make sure to connect cables to terminal properly and terminal cover should close firmly. 
Otherwise,  over heating at terminal contact, fire or electric shock might occur.

Make sure that there is no dust on  any connected points of electric cables and fix firmly.
Otherwise, fire or electric shock might occur. 

s

s

s

The clearances of the
unit from top, left, right
and front are specified
in figure below. At least
three of the above sides
must be open air.

For outdoor unit installation,allow  
at least 2 sides of space around  
the unit to ensure ventilation flue. 

200mm

above 

s

Please mount the Outdoor unit of stable ground to prevent vibration and increase of noise level.

s

Decide the location for piping after sorting out the different types of pipe available.

s

When removing side cover, please pull the handle after undoing the hook by pulling it downward. Reinstall the side cover in the 

CONDENSED WATER DISPOSAL OF OUTDOOR UNIT

s

There is holes on the base of Outdoor unit for condensed water to exhaust.

s

In order to flow condensed water to the drain, the unit is installed on a stand or a block so that the unit is 100mm above the 

ground as shown figure.  Join the drain pipe to one hole.

s

After installation, check whether the drain pipe clings to the base firmly.

s

Install the outdoor unit horizontally and make sure that condensate drains away.

s

In case of using in chilly area

pecially, in case that there are many snows by very  cold in chilly area, condensed water freezes

  on the base and may result not to drain.  In this case, please remove the bush and the drain pipe at the bottom of unit.(Left and 

  

center near discharge portion of air, each 1 place).It becomes smooth drain.Ensure that the distance from the drain hole to
the ground is 250 mm or more.

 CAUTION

s

Do not touch the suction port, bottom surface,or aluminum fin of the outdoor unit.Failure to do so   
may cause an injury.

above

BASE

 

 DRAIN PIPE

70mm

above

100mm

above

100mm

RAC-18WPC/RAC-25WPC

RAC-18WPC/RAC-25WPC

Pull downward

Pull downward

Pull downward

re verse order of the removal.

Dimension of Mounting

Stand of the Outdoor unit

(unit : mm)

RAC-35WPC

330

310

(10)

(10)

10

35

50

12

125

Mounting Stand

Mounting Stand

RAC-50WPC

 DRAIN PIPE

DRAIN HOLE

BASE

Outer diameter :

 

16 mm or more

Outer diameter :
16 mm or more

Outer diameter :
16 mm or more

 

BUSH

Push Push

DRAIN HOLE

Please face this side
(suction side) of the
unit to the wall.

RAC-35WPC

Please remove side cover 
when connecting the piping 
and connecting cord.

Please face this side
(suction side) of the
unit to the wall.

Please remove side cover 
when connecting the piping 
and connecting cord.

Please face this side(suction 
side) of theunit to the wall.

Please remove side 
cover when connecting 
the piping and connecting 
cord.

RAC-50WPC

RAC-18WPC/RAC-25WPC

RAC-35WPC

RAC-50WPC

 DRAIN PIPE

DRAIN HOLE

BASE

BUSH

2

BUSH

Figure showing the Installation of Outdoor Unit.

57

Mounting Stand

Bush

Bush

Bush

(35WPC)

(50WPC)

Air outlet

When“ heating”operation is performed, 
cool  air  blows and when “cooling” or 
“dehumidifying” operation is performed, 
warm air blows.

Drain hose

Drains the dehumidified water from the indoor unit to the
outdoor during “cooling” or “dehumidifying” operation.

Piping and Wiring

Air inlets (Rear and left sides)

MODEL

WIDTH (mm)  HEIGHT (mm)  DEPTH (mm)

750

548

288

600

299

660

530

278

RAC-18WPC, RAC-25WPC 

RAC-35WPC

RAC-50WPC

792

About the outdoor unit:

s

When “Stop” is selected during operation
of the indoor unit, the fan of the outdoor
unit continues turning for 10 to 60
seconds to cool the electric parts down.

s

In heating operation, condensate or
water due to defrosting will flow.
Do not cover the drain port of the outdoor
unit because such water may freeze in
the chilly area.

s

When the outdoor unit is hung on the
ceiling, install the bush and drain pipe
on the drain port and drain water.

give clearance as wide 
as possible

RAC-18WPC

RAC-25WPC

RAC-35WPC

RAC-50WPC

OUTDOOR UNIT

MODEL

EN

1

 WARNING

E OF INST

G

A

FINAL ST

N

OI

T

A

ALL

Power Source And Operation Test

Power Source

 WARNING

s

Never remodel the power plug nor extend the long-distance
cord.

s

Keep additional length for the power cord and do not render
the plug under external force as this may cause poor contact.

s

Do not fix the power cord with U-shape nail.

s

The power cable easily generates heat. Do not bring the
cable together with a wire or vinyl tie.

Operation test

s

Please ensure that the air conditioner is in normal operating
condition during the operation test.

s

Explain to your customer the proper operation procedures as
described in the user' s manual.

s

If the indoor unit won't operate, check the cable for correct
connection.

s

Turn on the lamp in the room where the indoor unit is installed
and check the remote controller for normal operation.

s

THIS APPLIANCE MUST BE EARTHED.

WARNING

Wiring of the Outdoor Unit

s

Please remove the side cover for wire connection.

Checking for the electric source and the voltage range

s

Before installation, the power source must be checked and necessary wiring work must be completed.

 To make the wiring capacity proper, use the wire gauge list below for the wiring from house distribution 

fuse box to the outdoor unit in consideration of the blocked rotor current.

s

Investigate the power supply capacity and other
electrical conditions at the installing location.
Depending on the model of room air conditioner to be
installed, request the customer to make arrangements
for the necessary electrical work etc.
The electrical work includes the wiring work up the
outdoor unit. In localities where electrical conditions
are poor, use of a voltage regulation is recommended.

s

Install outdoor for the room air conditioner within the
reaching range of the line cord.

WARNING

s

The naked part of the wire core should be 10mm fix it to the terminal tightly. Then
try to pull the individual wire to check if the contact is tight. Improper insertion may
burn the terminal.

s

Be sure to use only wire specified for the use of air-conditioner.

s

Please refer to the manual for wire connection and the wiring technique should
meet the standard of the electrical installation.

s

There is an AC voltage drop between the LN terminal if the power is on. Therefore,
be sure to remove the plug from its socket.

s

When the fuse (F5 or F6) has been blown out by the improper connection of power  
cable, it can be restored by the attached reserve fuse.
Please exchange the blown-out fuse after making sure the right connection.    

 WARNING

Outer

Diameter (Ø)

For R22 tool

6.35 (1/4")

1.0

9.52 (3/8")

1.0

0 - 0.5

0 - 0.5

0 - 0.5

1.0

12.7 (1/2")

cover

RAC-35WPC

L N 1 2 3

cover

0

5

C

P

W

RAC-

L N 1 2 3

Copper pipe

Trimming tool

Before flaring, please put on the flare nut.

A

Die

Die

Copper pipe

s

Please use
exclusive tool for
refrigerant R410 .

2

Please be careful when bending 
the copper pipe.
Screw in manually while adjusting 
the center. After that, use a torque
wrench to tighten the connection.

Torque
wrench

Flare nut

Wrench

3

Remove of Air From The Pipe And Gas Leakage Inspection

AL

V

REMO

AIR 

Procedures of using Vacuum Pump for Air Removal

As shown in right figure, remove the cap
of valve core.  Then, connect the charge
hose. Remove the cap of valve head.
Connect the vacuum pump adapter to the
vacuum pump and connect the charge
hose to the adapter.

1

Fully tighter the "Hi" shuttle of the manifold
valve and completely unscrew the "Lo"
shuttle.  Run the vacuum pump for about
10-15 minutes, then completely tighten the
"Lo" shuttle and switch off the vacuum
pump.

s

Loosen the spindle of the service valve
with small diameter by 1/4 turn and
tighten the spindle immediately after 5
to 6 seconds.

s

Remove the charging hose from the
service valve.

2

Completely unscrew the spindle of the
service valve (at 2 places) in anticlockwise
direction to allow the flow of refrigerant
(using Hexagonal Wrench key).

3

Tighten the cap of valve head.  Check the
cap's periphery if there is any gas leakage.
The task is then completed.

4

The body of service valve

Cap of
valve core

Hexagonal wrench Key

Cap of valve head

   Gas leakage inspection

Please use gas leakage detector to check if leakage occurs at

 connection of Flare nut as shown on the right.

If gas leakage occurs, further tighten the connection to stop leakage.

1

Preparation of Pipe

s

Use a pipe cutter to cut the copper pipe and remove burr.

Cap of valve
head

When the meter reaches - 101KPa
(-76cmHg) during pumping fully
tighten the shuttle.

Meter showing
pressure

Closed

R410A
Manifold
valve

Vacuum
pump

Valve

Charge
hose

Vacuum
pump
adapter

When pumping starts, slightly
loosen the flare nut to check of
air sucked in.  Then tighten the
flare nut.

Valve

RAC-18WPC/RAC-25WPC

T

erminal marking

L N 1 2 3  

 cover

Cord band

Earth 

terminal

Earth 

terminal

s

Remove burr and jagged edge will cause leakage.

s

Point the side to be trimmed downwards during 
trimming  to  prevent  copper chips from entering 
the pipe.

 CAUTION

s

s

s

s

s

Leave some space in the connecting cord for maintenance purpose and be
sure to secure it with the cord band. 
Secure the connecting cord along the coated part of the wire using the cord
band.Do not exert pressure on the wire as this may cause overheating or fire.

If you cannot attach the side plate due to the connection cord, please press the connecting 
cord in the direction to the front panel to fix it.
Be sure that the hooks of the side cover fixed in certainly. Otherwise water leakage may occur
and this causes short circuit or faults.
The connecting cord should not touch to service valve and pipes. 
(it becomes high temperature  in heating operation.)

CONNECTION O

PO 

F

WER CORD

s

s

s

N OF REFR

OI

T

ALLA

ST

NI

IGERA

TING PIPES A

AV

O

R REM

ND AI

L

 CAUTION

s

In case of removing flare nut of a indoor unit, first remove a nut of small 
diameter side, or a seal cap of big diameter side will fly out. Free from

 water into the piping when working.

s

Be sure to tighten the flare nut to the specified torque with a torque wrench.
If the flare nut is overtightened, the nut may be split after a long period has

 passed, and may cause a refrigerant  leak.

Procedures of Wiring

160mm

10mm

100mm

 

1

2

3

Connecting cord

Strip 
wires

Green + 
Yellow

20mm

Outdoor Unit

Indoor Unit

 

Connecting Cord

AC 220-230V
1ø 50Hz

1  2  3

1  2  3

Detail of Cutting the Connecting Cord

Outdoor Unit

Wire length

2

IMPORTANT

Fuse Capacity

RAC-18/25/35WP
RAC-50WPC

25A time delay fuse

Wire cross-section

Pipe Connection

Cord band

Cord band

6.35 (1/4")

9.52 (3/8")

12.7 (1/2")

6.35 (1/4")

9.52 (3/8")

13.7-18.6 (140 - 190)

34.3-44.1 (350 - 450)

44.1-53.9 (450 - 550)

19.6-24.5 (200 - 250)

19.6-24.5 (200 - 250)

12.7 (1/2")

29.4-34.3 (300 - 350)

12.3-15.7 (125 - 160)

Small diameter side 

Outer diameter 

of pipe (ø)

Large diameter side 

Small diameter side 

Large diameter side 

Valve core cap

Torque N·m 

(kgf·cm)

Valve

head cap 

For R410A tool

A (mm) Rigid Flaring Tool

1.5mm

2

2.5mm

2

4.0mm

up to    6m
up to  15m
up to  20m

A

L N

C 15A time delay fuse

Selecting the installation location: Suitable location that will reduce the impact 

from rain and direct sun that may affect the unit performance.

Besides,ventilation must be good and clear of obstruction .

<0016693Y>

above 

100mm

Earth 

terminal