background image

SAFETY PRECAUTION

 

Read the safety precautions carefully before operating the unit.

  The contents of this section are vital to ensure safety. Please pay special attention to the following sign.

  

WARNING ........ Incorrect methods of installation may cause death or serious injury.

  

CAUTION ......... Improper installation may result in serious consequence.

  

The sign in the  gure indicates prohibition.

 

Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit 
as described in the user’s manual.

!
!

WINDOW  TYPE  ROOM  AIR  CONDITIONER 
OPERATION  AND  INSTALLATION  MANUAL

PRECAUTIONS DURING INSTALLATION

  Please ask sales agent or quali ed technician for the installation of the unit. Water leakage, 

short circuit or  re may occur if install the unit improperly.

  Please use earth line.

  Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line 

of telephone. Improper installation of earth line may cause electric shock.

  A circuit breaker should be installed depending on the mounting site of the unit. Without 

a circuit breaker, the danger of electric shock exists.

 Do not install near location where there is  ammable gas. The unit may catch  re  if 

 ammable gas leaks around it.

  If drain pan is used, please ensure that when installing the drain hose, water is able to 

 ow freely without any obstruction.

CAUTION

!

!

WARNING

PRECAUTIONS DURING SHIFTING OR MAINTENANCE

●  

If abnormal situation arises (like burning smell), please stop the unit and turn off the 
circuit breaker. Fault, short circuit or  re may occur if the unit is continue to operate under 
abnormal situation.

 

Please contact your agent for maintenance. Improper maintenance may cause electric 
shock and  re.

 

Please contact your agent if need to remove and reinstall the unit. Electric shock or  re 
may occur if you remove and reinstall the unit improperly.

WARNING

!

MODEL

RA-08LEDF
RA-10LEDF
RA-13LEDF

PARTS IDENTIFICATION AND OPERATIONS

1

 Cabinet

2

 Suction 

Grille

3

 Front 

Cover

4

 Horizontal 

De ectors

5

 Vertical 

De ector 

6

  Air Exhaust Lever

7

  Switch Panel Cover

Model

RA-08LEDF
RA-10LEDF

RA-13LEDF

Width

18 

1

2

”, 470mm

22 

3

64

”, 560mm

Height

13 

1

2

”, 345mm

14 

3

4

”, 375mm

Depth

25 

3

16

”, 640mm

27 

29

32

”, 709mm

CONTROL PANEL

INDICATION LAMP

TEMPORARY SWITCH

Use the temporary switch for start or stop operation when operation cannot be done with the remote controller.

By pressing the temporary switch, [use non-conductor stick (for example: toothpick),] the operation will follow previous 

 

operation mode.

When the operation is done using the temporary switch, after the power source is turned off and is turned on again, the 
operation is done in automatic mode.

AIR DEFLECTORS

Vertical de ectors at both sides of outlets can be set to 
either auto-swing or static position to direct discharge air 
rightward, leftward or forward direction.

Horizontal de ectors at both sides of the outlets can 
be set to direct discharge air upward, downward or 
forward direction.

VERTICAL DEFLECTORS

HORIZONTAL DEFLECTORS

To avoid dew forming on the de ectors which eventually may drip to the  oor, please do not adjust horizontal de ectors 
extremely downward position or vertical de ectors extremely leftward or rightward position during cool operation for a long 
time.
Also, do not adjust the vertical de ectors position by hand or any other object.

!

CAUTIONS

AIR EXHAUST LEVER

AIR PURIFYING FILTER

Set the air exhaust lever to the down (

OPEN) position for air ventilation in 

the room. The air exhaust lever should normally be kept in up (

CLOSE) 

position during cooling operation and in the case of typhoon.

NOTES ON OPERATION

TEMPERATURE AND HUMIDITY

Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21°C (70°F). Recommended 
operation humidity should be below 80%. Continuous operation at over 80% humidity (indoor) will cause some dews form 
on the outlet grille and de ectors of the unit.

NOISE

In a quiet environment during the starting or stopping the operation, phenomena like  owing sound of refrigerant in the 
refrigerating cycle and rubbing noise from the fan casing may occasionally occur, but this is normal for the operation.
Water will be condensed on the evaporator coil and collected in the bottom tray, it is picked up by the condenser fan and 
blown onto the condenser coil, this creates a “splashing” sound which is normal.

ODOR

The odor will possibly be emitted from the room air conditioner especially at the starting of operation and in a high 
humidity condition. This is not abnormal phenomena because of the various kind of odors emitted by smoke, food stuffs, 
cosmetics and others which may stick to the room air conditioner. So, the pre- lter and the evaporator regularly must be 
cleaned to reduce the odor.

THE IDEAL WAYS OF OPERATION

Suitable Ro

om

 Temperature

     

   

Warning

Freezing temperature 
is bad for health and a 
waste of electric power.

!

Install curtain or blinds

It is possible 
to reduce heat 
entering the room 
through windows.

Ventilation

       

Caution

Do not close the room for a long period of 
time. Occasionally 
open the door and 
windows to allow the 
entrance of fresh air.

!

Do Not Forget To Clean The Pre-Filter

Dusty pre- lter will reduce the air 
volume and the cooling ef ciency. 
To prevent from wasting electric 
energy, please clean the pre- lter 
every 20 days.

Please Adjust Suitable Temperature 

For Baby And Children

Please pay attention to the 
room temperature and air  ow 
direction when operating the 
unit for baby, children and old 
people who have dif culty in 
movement.

FOR USER’S INFORMATION

The Air Conditioner And The Heat Source In The Room

    Caution

If the amount of heat in the room is above the cooling capability of the air conditioner (for 
example: more people entering the room, using heating equipments and etc.), the preset 
room temperature cannot be achieved.

!

When Lightning Occurs

    Warning

To protect the unit during lightning, please stop operating the unit and remove the plug 
from the socket.

!

<

IA1049: A 

>

TEMPORARY SWITCH
Use this switch to start operation and stop 
when the remote controller does not work. 
Normally do not use this switch

POWER SWITCH

DEHUMIDIFY LAMP

OPERATION LAMP

TIMER LAMP

1. Pull and remove the suction grille

2. Remove the pre- lter

3.  Install the air purifying  lter  in 

the frame

4.  Install back the pre- lter and 

close the suction grille

Always stop the operation before installing the air purifying  lter.

Air purifying  lter is washable and can be use for 1 year time. Type number for this air purifying  lter is <SPX-CFH8W>. 

Please use this number for ordering when you want to renew it.

INS RA-08-10-13LEDF   1

2/8/13   12:38 PM

Summary of Contents for RA-08LEDF

Page 1: ...ly leftward or rightward position during cool operation for a long time Also do not adjust the vertical de ectors position by hand or any other object CAUTIONS AIR EXHAUST LEVER AIR PURIFYING FILTER Set the air exhaust lever to the down OPEN position for air ventilation in the room The air exhaust lever should normally be kept in up CLOSE position during cooling operation and in the case of typhoo...

Page 2: ...h at bottom corner Clean the front cover and suction grille with a soft dry cloth When it is excessively dirty wipe it with a soft cloth dampened with mild soap then wipe it again thoroughly with a soft dry cloth The suction grille can also be removed and be washed with water and mild soap Remove the suction grille in the following manner 1 Remove the suction grille by pulling the bottom corner an...

Page 3: ...button Press this button to setting the turn on time Precautions O Do not put the remote controller in the following places O In direct sunlight O Near a heat source O Handle the remote controller carefully Do not drop it on the oor and away from water O Once the air conditioner stops it will not restart for about 3 minutes unless you turn the power switch off and on or unplug the power cord and p...

Page 4: ...eached HI High fan speed MED Medium fan speed LOW Low fan speed Set the desired room temperature with the TEMPERATURE button the display indicates the setting The range of 25 28 C is recommended as the room temperature for cooling The temperature setting and the actual room temperature may vary depending on conditions Press the STOP button to stop operation Q As the settings are stored in memory i...

Reviews: