10
/
12
5. Hardware specifications
*1: If the finger positioning is incorrect, authentication may fail even with the applicable finger
width.
*2: It is recommended to connect the Biometric Reader directly to the USB port of your PC. If
you need to connect the Biometric Reader via a USB hub, use a self-powered hub.
*3:When you reconnect the Biometric Reader to your PC after a disconnection, use the same
USB port to which the Biometric Reader was connected.
*4:When Biometric Reader is connected to the USB 3.0 port or USB 2.0 port, Biometric Reader
is recognized as a USB 1.1 device.
6. Troubleshooting
Name
Biometric Reader
Model
PC-KCB120
Applicable finger width *1
Wider than 10 mm/0.4 inch and narrower than 25 mm/1 inch
Interface
USB 1.1 *2 *3 *4
Dimensions
Approx.
69mm/2.7inch(W) x 97mm/3.8inch(D)x 79mm/3.1inch(H)
(USB cable not included)
Weight
Approx.
133g/4.7oz (USB cable not included)
Maximum Current
Consumption
DC 5V 500 mA (Bus powered)
Environment
Conditions
(Operation)
Operating
temperature
5 to 35 degrees C (41 to 95 degrees F)
Operating
Humidity
20 to 80% Rh (Do not allow condensation)
Environment
Conditions
(Storage)
Storage
Temperature
-10 to 60 degrees C (14 to 140 degrees F)
Storage
Humidity
20 to 80% Rh (Do not allow condensation)
Smart Card
ISO/IEC 7810 ID-1 sized