2.4 Test of solenoid valve/pump
- The operation confirmation of solenoid valve and pump is performed.
(1) Supply valve
(MV1)
(2) Replenishment valve
(MV2)
(3) Recovery valve
(MV3)
(4) Agitation valve
(MV4)
(5) Circulation valve
(MV5)
(6) Pressure relief valve
(MV6)
(7) Makeup ink valve
(MV7)
(8) Cleaning valve
(MV8)
(9) Shutoff valve
(MV9)
(10) Viscometer coil
(MV10)
(11) Pump
With respect to the
password protection,
refer to " 2.1 setting of
service personnel
maintenance mode"
- Perform this test in a "stop" state.
(In an operating state, only an operating state is displayed.)
1
Press solenoid valve/pump test at the second page of the service
maintenance screen.
When the previous menu and the next menu are not displayed in the maintenance menu,
set to the service personnel maintenance mode by the password protection.
The operating state of the solenoid valve and the pump is displayed.
(Confirm the operation by an operating sound.)
Open
: The solenoid valve is opened.
Close
: The solenoid valve is closed.
Operated : The pump is operated.
Stop
: The pump is stopped.
2-16
Summary of Contents for IJ PH
Page 1: ...Service Manual HITACHI Printer Model PH Revision Aug 2011 Version First edition ...
Page 2: ... Revision of PH service manual Revision Chapter Revised Page ...
Page 13: ...1 2 2 Main body internal PH D 1 8 ...
Page 80: ...3 25 3 25 Circuit diagram of EZJ95 ...
Page 201: ...7 1 7 Attached Drawing 7 1 Circulation System Diagram ...
Page 202: ...7 2 7 2 Electrical Connection Diagram ...
Page 205: ...7 5 7 4 Dimensions around charge electrode and deflection electrode Nozzle diameter 65 um ...