Status
Universal Replicator Pair Status
Primary
Secondary
•
SSWS is displayed by CCI, from which the
horctakover command is issued.
•
Storage Navigator displays this status as PSUS or
PSUE.
PFUL
If data in the journal volume exceeds 80%, pair status
changes to PFUL. The write data that inflows then is
monitored during the Data Overflow Watch.
PFUL status is displayed by CCI. Storage Navigator
displays this status as PAIR.
R/W enabled
R enabled
Table 6-4 Pair status versus TrueCopy/Universal Replicator commands
-
TrueCopy/Universal Replicator command
paircreate
pairsplit
pairresync
# Status
Copy
Nocopy
-r or -rw
option
-P option
-S option
Resync
1
SMPL
Accepted 2
Accepted 3
Rejected
Rejected
Acceptable
Rejected
2
COPY
Acceptable
Acceptable
Accepted 4
Rejected
Accepted 1
Acceptable
3
PAIR
Acceptable
Acceptable
Accepted 4
Accepted 4
Accepted 1
Acceptable
4
PSUS
Rejected
Rejected
Acceptable
Acceptable
Accepted 1
Accepted 2*
5
PSUE
Rejected
Rejected
Acceptable
Acceptable
Accepted 1
Accepted 2*
6
PDUB
Rejected
Rejected
Rejected
Rejected
Accepted 1
Accepted 2*
Legend:
Accepted = Accepted and executed. When the operation terminates normally, the status changes to the
indicated number.
Acceptable = Accepted but no operation is executed.
Rejected = Rejected and operation terminates abnormally.
Pairsplit of a TrueCopy Async volume is returned after verification of state
transition that waits until delta data is synchronized from P-VOL to S-VOL.
Note:
In the case of the SSWS status after SVOL-SSUS-takeover execution,
the
pairresync
command (from P-VOL to S-VOL) is rejected because the
delta data for S-VOL becomes dominant, and its status is expected to be
using the
-swaps(p)
option of
pairresync
. If the
pairresync
command
(from P-VOL to S-VOL) is rejected, confirm this special status using the
-fc
option of the
pairdisplay
command.
The following table shows the relation of command acceptances for paired
status and ShadowImage.
Data replication operations with CCI
6-21
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Page 529: ...Command Control Interface User and Reference Guide ...