![Hitachi HUS VM User And Reference Manual Download Page 201](http://html.mh-extra.com/html/hitachi/hus-vm/hus-vm_user-and-reference-manual_145969201.webp)
Step
Operation
overview
Description
Executed command
17
Setting MP
blade of LDEV
Set MP blade of created LDEV.
raidcom modify ldev
-ldev_id <ldev#>
-mp_blade_id <mp#>
18
Displaying
LDEV
information
Display information of created
LDEV and confirm the result of
executing the command.
raidcom get ldev -ldev_id
<ldev#> … [-cnt <count>]
[-key <keyword>]
19
Creating LU
path
Specify port, map LDEV to LUN
and create an LU path.
raidcom add lun -port
<port#>
[<host group name>]
-ldev_id <ldev#>
[-lun_id<lun#>]
20
Displaying LU
path
information
Display LU path information
and confirm the result of
executing the command.
raidcom get lun -port
<port#>
[<host group name>]
Creating external volumes (iSCSI)
Use the following provisioning operations to create LDEVs of external volumes
using iSCSI and make the LDEVs available from the host.
Step
Operation
overview
Description
Executed command
1
Setting the
port attribute
of the local
storage system
Set the port attribute of the
local storage system to the
External (ELUN) port.
raidcom modify port -port
<port#> -port_attribute
ELUN
2
Searching the
iSCSI target of
an external
storage system
Display information about the
iSCSI target of the external
storage system that has the
specified IP address and is
connected to the External
(ELUN) port.
raidcom discover
external_iscsi_name
-port <port#>
-address <external IP
address>
3
Registering the
iSCSI name of
the iSCSI
target for an
external
storage system
Register the iSCSI target to
connect as an external storage
system.*
raidcom add
external_iscsi_name
-port <port#>
-iscsi_name <external
iscsi name>
-address <external IP
address>
4
Setting CHAP
authentication
information for
connecting to
the iSCSI
target of an
external
storage system
When CHAP authentication is
used for connection to external
storage systems, set the CHAP
user name and a password
(secret) used by the iSCSI
target of an external storage
system for authenticating the
External (ELUN) port of the
local storage system.
raidcom modify
initiator_chap_user
-port <port#>
[-chap_user <username> ]
[-secret]
5
Setting CHAP
authentication
When CHAP authentication is
used for connection to external
raidcom modify
external_chap_user
-port <port#>
Provisioning operations with CCI
5-47
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Page 529: ...Command Control Interface User and Reference Guide ...