360
ADSR—A/D start register
H'C6
A/D converter
Bit
Initial value
Read/Write
7
ADSF
0
R/W
6
—
1
—
5
—
1
—
4
—
1
—
3
—
1
—
0
—
1
—
2
—
1
—
1
—
1
—
A/D start flag
0
[Read]
Indicates the completion of A/D conversion
1
[Write]
Stops A/D conversion
[Read]
Indicates A/D conversion in progress
[Write]
Starts A/D conversion
TMY—Timer mode register Y
H'CD
Timer Y
Bit
Initial value
Read/Write
7
TMY7
0
R/W
6
—
1
—
5
—
1
—
4
—
1
—
3
—
1
—
0
TMY0
0
R/W
2
TMY2
0
R/W
1
TMY1
0
R/W
Count select
1
0
Internal clock ø/8192
1
Internal clock ø/2048
0
0
0
0
0
Internal clock ø/512
1
0
1
Internal clock ø/256
1
0
0
Internal clock ø/64
0
1
1
Internal clock ø/16
0
1
0
Internal clock ø/4
1
1
1
External event (TMCIY): count on rising
edge/falling edge
1
1
Auto-reload function select
1
0
Interval function selected
1
Auto-reload function selected