GR4000 Installation Guide Version 1.00 - Preliminary
66
520-10-014-20X
2.4
Power Supply Equipment
2.4.1
Equipment for AC Power Supply Unit
(1) AC Power Outlet
Use the power outlet which matches the following specifications.
Table 2.4-1 Specification of AC input power
GR/GS4000 Model
Input voltage
AMP’S (MAX)
Phase
Frequency (Hz)
80EM 100-120VAC/200-240VAC
8.5/5A × 2
Single
50/60
160EM 100-120VAC/200-240VAC
8.5/5A × 4
Single
50/60
Table 2.4-2 Specifications of GR/GS4000 power cords
GR/GS 4000 Model
No. Connector
(on the device
side)
Cable
Ratings
Cable
Length
Wire Type
Plug
(power
facility)
80EM 160EM
1 IEC-320-C13
125V 15A
Comply with
the standard
of each
country.
2.0mm
2
/3 or
more
Comply with
the standard
of each
country.
2 IEC-320-C13
250V 10A
Comply with
the standard
of each
country.
2.18mm
2
/3 or
more
Comply with
the standard
of each
country.
WARNING: WHEN CONNECTING THE DEVICE TO THE AC POWER SUPPLY UNIT, USE
ONLY GROUNDED POWER OUTLETS. FAILING TO USE GROUNDED OUTLETS
CREATES A SHOCK HAZARD. FURTHERMORE, YOU COULD INTRODUCE
UNWANTED ELECTRICAL NOISE INTO THE DEVICE, WHICH COULD DEGRADE
PERFORMANCE.
V
V
V
V