GR4000 Installation Guide Version 1.00 - Preliminary
40
520-10-014-20X
1.4.3
BCU-RL8ME
This is the basic control module for GR4000
-
320E (AC). The BCU
-
RL8ME has the
following hardware specification:
Memory card slot: 2 slots
Memory slot: 4 slots
(
Standard
:
256MB×1 Max.
:
256MB×4
)
AUX port: 1 port
CONSOLE port: 1 port
CONSOLE
(
10BASE
-
T
/
100BASE
-
TX
)
port
:
1 port
(1) Outer Appearance
As for the LED, see Table 1.4-3.
Figure 1.4-4 Front View of BCU-RL8ME
(2) Connector
As for the cables to be connected to each connector, refer to the Chapter 3.
(3) LED (Light Emitting Diode) and Switches
Table 1.4-3
LED Indications and Switches on the BCU-RL8ME Front Panel
Name
Type or color
Role
Action Status
LAMP TEST
Switch
Lamp test
Lamp test switch
(
non-lock
)(
Note 1
)
RESET
Switch
Manual reset of a
device
Reset switch
(
non-lock
)
BCU
ALTERNATE
Switch
Switching of a
system
Switch for the system switching
(
non-lock
)
EMA
SUPPRESS
LED
:
Yellow
Shows the action
status related to the
system switching.
ON: System switching is restrained.
(
including the
case in which a single BCU is used
)
OFF
:
Normal condition
(
System switching occurs.
)
ACTIVE
LED
:
Green
Shows the action
status related to the
redundant system
of BCU.
ON
:
BCU is operated using the active system.
OFF: BCU is operated using the standby system.
POWER
LED
:
Green
Shows the
condition of power
input.
ON
:
Power output in BCU is normal.
OFF
:
Power output in BCU is abnormal, or BCU is
powered off.
READY
LED
:
Green
Shows the action
status of a device.
ON
:
Operation is possible.
OFF: A failure was found in BCU , or BCU is being
initialized.
Memory card
slot 0
CONSOLE port
CONSOLE(10BASE
-
T
/
100BASE
-
TX) port
LED
LED
7SEG
LED
Switch
AUX port
Memory card
slot 1
LED