GR4000 Installation Guide Version 1.00 - Preliminary
32
520-10-014-20X
(2) LED
In the AC200V power supply unit of GR4000-320E (AC), the action status is indicated
by the combination of the two LEDs as shown in Table 1.3-3.
Table 1.3-2
LED Indications on the POW
-
MSACE Front Panel
Name
POWER
(
LED
:
Green
)
ALARM
(
LED
:
Red
)
Action Status
Power ON
Power OFF
Output voltage is normal.
Power OFF
Power ON
Output voltage is abnormal.
Power OFF
Power OFF
Power is OFF or the output voltage is abnormal.
(
Note 1
)
(Note 1)
:
There is the possibility that both POWER LED and ALARM LED are powered off depending on
the contents of a trouble.
(3) Accessories
The AC200V power cable (length: 2.5m) is provided together with POW
-
MSACE.This
cable is supplied only for customers in Japan.
Figure 1.3-4
Power Cable
WARNING: USE THE POWER CABLE PACKED ALONG WITH A CHASSIS. IF YOU USE A
POWER CABLE OTHER THAN THIS, IT COULD CAUSE A FIRE OR AN
ELECTRIC SHOCK. IN ADDITION, DO NOT USE THIS POWER CABLE FOR THE
DEVICES OTHER THAN THE GR4000 MODELS. IF YOU DO, IT COULD CAUSE A
FIRE OR AN ELECTRIC SHOCK.