GR4000 Installation Guide Version 1.00 - Preliminary
520-10-014-20X
95
3.3
The Setup Terminal and Cable Connections
3.3.1
Setup Terminal
Prepare a personal computer or a workstation which supports the following features
mentioned in Table 3.3-1 below.
Table 3.3-1
Specifications Required for Setup Terminals
Category Specification
Communication port
RS
-
232C
Communication software (Note 1)
Hyperterminal utility in Windows 95/98 or other similar terminal
communication software.
Transfer protocol
ZMODEM
Parameter
8-bits data, 1 stop bit, no parity
Communication
Settings
Speed in bps (Note 2)
19200bit
/
s
,
9600bit
/
s
,
4800bit
/
s
,
2400bit
/
s
,
1200bit
/
s
Other features
CD
-
ROM drive (Note 3)
(Note 1) Used for the setup of configuration information through dialogue.
(Note 2) Set to default of 9600 bps as shipped from factory.
(Note 3) Used for the re-installation of software.
3.3.2
Connecting Cable
(1) RS-232C Cross Cable
The RS-232C cable, a cross-cable having a D-sub 9-pin (female) on each end, is
required to connect the GR4000 to a setup terminal. Table 3.3-2 below shows the pin
arrangement of this cable.
Table 3.3-2
Pin Arrangement of RS
-
232C Cross Cable
Router Side: 9 Pins (Female)
Console Side: 9 Pins (Female)
No
Pin number
Signal name
Physical Connection
Pin number
Signal name
1 5
SG
5
GND
2 3
SD
2
RX
3 2
RD
3
TX
4 7
RS
1
DCD
5 8
CS
8
CTS
6 1
CD
7
RTS
7 6
DR
4
DTR
8 4
ER
6 DSR