After the path is recovered, the remote path is automatically recovered. If
you recover the physical path but the remote path does not recover,
contact Hitachi Data Systems customer support.
2
.
Resynchronize the pair.
a
.
Confirm that the S-VOL I/O mode is Local.
pairdisplay -g oraHA -fxce -IH1
Group PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence, %,P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
oraHA dev1(L) (CL1-C-0, 0, 0)322222 4444.S-VOL SSWS
NEVER , 100 2222 - - 0 - - - - L/L
oraHA dev1(R) (CL1-A-0, 0, 0)311111 2222.P-VOL PSUE
NEVER , 100 4444 - - 0 - - - - B/B
b
.
At the secondary system, resynchronize the pair.
pairresync -g oraHA -swaps -IH1
The volume on the primary system changes to an S-VOL, and the
volume on the secondary system changes to a P-VOL.
c
.
Confirm that the P-VOL and S-VOL pair statuses change to PAIR
(Mirror (RL)).
pairdisplay -g oraHA -fxce -IH0
Group PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence, %,P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
oraHA dev1(L) (CL1-A-0, 0, 0)311111 2222.S-VOL PAIR
NEVER , 100 4444 - - 0 - - - - L/M
oraHA dev1(R) (CL1-C-0, 0, 0)322222 4444.P-VOL PAIR
NEVER , 100 2222 - - 0 - - - - L/M
pairdisplay -g oraHA -fxce -IH1
Group PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence, %,P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
oraHA dev1(L) (CL1-C-0, 0, 0)322222 4444.P-VOL PAIR
NEVER , 100 2222 - - 0 - - - - L/M
oraHA dev1(R) (CL1-A-0, 0, 0)311111 2222.S-VOL PAIR
NEVER , 100 4444 - - 0 - - - - L/M
3
.
Using the alternate path software, resume I/O to the S-VOL (P-VOL
before the failure).
I/O from the server might resume automatically.
4
.
Reverse the P-VOL and the S-VOL if necessary.
Related topics
•
•
•
SIMs related to GAD on page 6-6
•
Reversing the P-VOL and S-VOL on page 6-51
Pair condition and recovery: primary system failure
The following table shows transitions for pair status and I/O mode, the
volumes accessible from the server, and location of the latest data when you
can no longer use the primary system due to failure.
Disaster recovery of global-active device
6-29
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Summary of Contents for G1000
Page 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...