Steps for recovery
1
.
Recover the path.
a
.
Using the alternate path software or other tools, identify the path that
cannot be accessed from the server.
b
.
Using SAN management software, identify the failure location; for
example, a host bus adapter, FC cable, switch, or other location.
c
.
Remove the cause of failure and recover the path.
2
.
Using the alternate path software, resume I/O from the server to the
recovered path (I/O may resume automatically).
Related topics
•
•
SIMs related to GAD on page 6-6
Pair condition and recovery: P-VOL failure (LDEV blockade)
The following table shows transitions for pair status and I/O mode, the
volumes that are accessible from the server, and the location of the latest
data when you can no longer use the P-VOL due to LDEV blockade.
Disaster recovery of global-active device
6-11
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide