102 | 108
E-Compact MP-BB3 Series
5.4. Transmitter Operating Temperature Configuration
The transmitter’s operating temperature is measured on the power modules’ transistors and is configurable
between 50°C (122 °F) and 60°C (140 °F).
Configuration is done through the front panel Menu: Setup Menu “PA Temperature Control”.
This configuration varies according to room temperature and the transmitter’s efficiency and is necessary
to optimize the operating temperature and equipment’s lifespan.
This configuration shall be made when the equipment is activated following the procedure below:
1. With the transmitter running at operational power for at least 30 minutes, access the web or the PA
USB interface to verify fan rotation.
2. Check fan rotation for all fans in all of the PA’s.
3. Temperature adjustment must be done in order to obtain fan rotations between 5500 rpm and 6000
rpm.
4. If the highest rotation is below 5500 rpm, the temperature control has to be lowered. If it is above 6000
rpm, temperature control shall be raised.
5. Configure temperature at Setup Menu “PA Temperature Control”. Lower or raise the temperature
according to description in step 4 above. It is recommended that the procedure starts in steps of 4 °C.
6. Once configured, wait 5 minutes until transistor temperature stabilizes.
7. Repeat steps 3 through 6 until fan rotation is within range (5500 rpm to 6000 rpm).
Summary of Contents for EC702MP-BB3
Page 68: ...68 108 E Compact MP BB3 Series VGS Carrier Software Version 1 75 1 70 1 71 1 78 ...
Page 84: ...84 108 E Compact MP BB3 Series B220 BIPHASIC 220VAC 2 PHASE 110VAC GND ...
Page 85: ...85 108 E Compact MP BB3 Series M220 SINGLEPHASE 220VAC 1 PHASE NEUTRAL GND ...
Page 106: ...106 108 E Compact MP BB3 Series Section 8 Attachments ...
Page 108: ...108 108 E Compact MP BB3 Series ...