84 | 106
E-Compact Medium Power
2. Activation.
The steps of this activation must be followed to avoid damage to the equipment.
1
st
Before Turn-On, Check if all on/off key
Drawers it’s “
off
”
2
nd
Trigger the circuit breaker on (
01
)
3
rd
Check if both the Exciter (Main and Backup) are
configured for the correct channel, the same as
the Mask Filter and the Antenna.
4
th
Check if both the Module Control CM8001 (Main
and Backup):
Chanel is the same of the Exciter (
02
)
The description of the Equipment is correct (
03
)
5
th
Check if the Main Exciter and Main Module
Control CM8001 are active.
6
th
Check if the Programmed Power in Main
Module Control CM8001 is 0 (ZERO) Watts:
Display Interface
>Measurements [2000] > Power [2100] >
Programmed Power [1/3]
7
th
Switch On the two Power Supplies (
04
) in the
MOD GV 40226 Drawer
8
th
Check the Drawer Communication Status.
In the Main Module Control Display Interface:
>Measurements [2000] > Communications
Status [2500]
Pxx =
OK
9
th
Check the
ALL
Power Supply and Current when
0 (Zero) Watts Transmitter FWD Power:
In the Main Module Control Display Interface:
>Measurements [2000] > Drawers [2300]
> Power Supply [2310]
Power Supply ≈ 45,5V
>Measurements [2000] > Drawers [2300]
> Current [2320]
I ≈ 0,30A (for each PA)
01
MC8001 Display - Second Home Screen (Status)
02
03
04