6.4. MOD 40215 EIA RF Output Line with Sample Probe
The 4.5. EIA RF Output Line with Sample Probe is a passive coaxial RF sample installed in the
Mask Filter RF output and has four independent RF outputs samples.
It has two signal samples for use in the non-linear adjustment, a sample for the reflected power
monitoring and a direct power monitoring sample.
6.4.1. Features
RF DIRECTION
RF IN
RF OUT
D - FWD
A - FWD
B - FWD
C - REF
Operation Frequency
470 to 806MHz CH14 to CH69
Max Power
5500 Watts
Insertion Loss (RF IN – RF OUT)
-0.13dB (MAX); -0.10dB (MIN)
RF OUT
Connection: 1-5/8” EIA Flange
Return Loss: -36dB (TYPICAL); -31dB (MIN)
Impedance: 50Ω
RF IN
Connection: 1-5/8” EIA Flange
Return Loss: -36dB (TYPICAL); -31dB (MIN)
Impedance: 50Ω