38 | 106
E-Compact Medium Power
# Parameter
Position # Description / Functionality
4/7 Control Module
Power Supply
2400
1/2 +3,3V : OK - Check de +3,3Vcc Ctrl Module Power Supply
+15V : OK - Check de +15Vcc Ctrl Module Power Supply
2/2 +5V : OK - Check de +5Vcc Ctrl Module Power Supply
+28V : OK - Check de +28Vcc Ctrl Module Power Supply
5/7 Communication
Status
2500
1/3 Drawers Communication Status (OK / Fail / -- “not present”)
P01 / P02 / P03 / P04 – Power Drawer 1 / 2 / 3 / 4
2/3 Drawers Communication Status (OK / Fail / -- “not present”)
P05 / P06 / P07 / P08 – Power Drawer 5 / 6 / 7 / 8
3/3 Control Module Communication Status
(OK / Fail / -- “not present”)
6/7 Software/Hardware
Version
2600
1/4 Control: Control Module Version
2/4 Drawers Version.
(
◀
or
▶
) Selects the Power Drawer
3/4 Digi: Ethernet Module Version
4/4 CIP Version / CIM Version
7/7 Eqp. Power Supply
2700
1/1 Eqp. Power Supply Measurements (OK / Fail)
15V / 8V 50V
[3000] - Main Menu
⇨
System Alarms/Log
[0000]
Main Menu
[1000]
Setup Menu
[2000]
Measurements
[3000]
System
Alarms/Log
[4000]
Remote Acces
This menu provides information on current and past alarms for preventive/corrective maintenance
purposes.
Before detailing access to the Sub-menus of this item, it is important to know what the alarms are and
their possible solutions..
There are two alarm lists; "Equipment Alarms", which refers to faults in the equipment as a whole and
"Drawers Alarms", which refers to faults in power amplifier drawers and thus impact the transmitter’s
operation reflected in the operation of the equipment.