DW-3 CHASSIS PLASMA DEFECT TROUBLESHOOTING PROCEDURE.

  

The Below Information relates to investigations related to a Defective Plasma when there is no Picture at all.

  

Use this section for P42H401, P42H4011, P50H401, P50H4011, P55H4011 and P55H401 and P42T501, 
P50S601, P50V701, P50X901, P50T501, P55H401, P55T501 and P60X901 Plasma Television. 

 
No Picture:

  

1. The Power Supply may not be producing the correct voltages. 
2. The Digital Module (Digi-Main) may not be producing correct 

turn on commands (Power 1 and 2).  

3. The Logic PWB may not be supplying the correct Vs/Va turn on 

commands (Vsago and Vcego). 

The Panel can have a defect of two natures.

  

1. The panel is shorted.  
2. The panel is defective, but not presenting a short.  

3.

Y-SUS and/or X-SUS may be defective (Shorted and or non-
working).

  

 
First monitor the front Power LED.

  

Does it turn on, then go completely off? (Indicates Shutdown), Power Supply not running. 
(Shutdown usually indicates a Short.)

  

Does it turn on and stay Green, but no picture. (No Shutdown), 

 

Power Supply running basic power supplies, but Vs/Va voltages not being produced.

  

 
PRELIMINARY OBSERVATION:

 

 

Next open the unit by removing the back cover. Check the following carefully by visual observation.

 

 

Power Supply PWB: Look very carefully around all mounting screws for cracks or PWB damage. 

DW-3 NO PICTURE TROUBLESHOOTING Page 1 of 10 

NOTE: It would be very helpful is you have 
one other document to accompany this one. 
(On our web site, see these models Things 
You Should Know section Power Supply 
Issues to download these documents.)  

DW-3 Power Supply Explanation.pdf 

http://www.hitachiserviceusa.com/service/
Seminars/Plasma-Web/DW3-Web/Fixes/ 
00-Things-Known.htm  

Continued on Next Page 

BUFFERS (Drivers) ON SDR Upper and/or Lower PWBs (50”~60”)

 

Take a moment to carefully observe the Buffer “Snot” Chips  
(Left Side black chips mounted on the SDR Upper and Lower PWBs).  
Look very closely for burns and/or small holes in these chips.

  

If any defect is seen, the PWB is defective. Replace this PWB and  
the Y-SUS if PWB not upgraded. Replace only SDR if PWB is upgraded

 

SDR U / L

 

Version 04 (02/05/2008) 

COF (Chip on Film) from Panel to A-BUS (42”)

 

Take a moment to carefully observe the COFs 

Chip on 

Film 

(Mounted on the flexible ribbon cables).

 

Look very 

closely for burns and/or small holes in these chips.

  

 
Look very closely for any ribbon cable damage on the 
connections to the Panel itself from the  
A-BUS PWBs.

 

If any defect is seen, the Panel is  

defective. (Note, some additional disassembly is required 
to see these COFs as they are on the  underside of the rib-
bon cable coming from the panel to the A-BUS L, R and 
C PWBs.) 

TO PANEL 

TO A-BUS CONNECTOR 

HOLES 

BUFFER 

BUFFER 

COF 

COF 

See Web site Things You Should Know 
Picture Issues Item 25 to determine if PWB 
is upgraded. 

Summary of Contents for Director's P60X901

Page 1: ...acks or PWB damage DW 3 NO PICTURE TROUBLESHOOTING Page 1 of 10 NOTE It would be very helpful is you have one other document to accompany this one On our web site see these models Things You Should Know section Power Supply Issues to download these documents DW 3 Power Supply Explanation pdf http www hitachiserviceusa com service Seminars Plasma Web DW3 Web Fixes 00 Things Known htm Continued on N...

Page 2: ...nd Vsago commands being high coming from the Logic PWB CN68 connector 42 Va CN64 pin 1 Vs 85V CN64 pin 7 Vs 85 5 CN64 pin 9 New for the DW 3 Chassis 50 Va 60V CN64 pin 1 Vs 80V CN64 pins 8 or 9 or 10 Note There is a great deal of information on our web site about how to Force the Power Supply to produce all of the above voltages to check the Power Supply PWB and how this Power Supply generates vol...

Page 3: ...en will be black but the bottom will have raster If the answer is 2 Green Power LED will go Green the Go Off Brief rise then collapse of the Vs and Va voltages This indicates a Load on the line Pull the CN 64 connector feeding Vs Va voltages to the X SUS Take an ohmage reading from the Va and Vs lines on each PWB This means you have to read the Connector on the Power Supply and the pulled connecto...

Page 4: ...f the answer is 3 No Vs Va activity This usually indicates either a dead load on the line or no Vsago Vcego commands from the Logic PWB CN68 First check Check the Va Vs turn on commands Remember The SBY 5V from CN63 pin 1 must be present before Vsago Vcego lines can function When the Power Button is pressed within moments Vcc5 1V should come when the Vcego and Vsago Commands go high See the next 4...

Page 5: ... GND n a n a n a n a 3 N C 0V 0V 2 6K n a 4 PoWERoFF 0V 0V 2 8K 5 ACCLoCK 3 3V 3 8V 11 1K 6 PoWER1 0V 4 8V 9 6K 7 PoWER2 0V 3 1V 10 5K 8 N C n a 3 3V 9 1K n a CNPPS to Digi Main PPM2 Pin Label SBY RUN Ohm Out In 1 5 6V 0V 5 6V 1 3K 2 5 6V 0V 5 6V 1 3K 3 5 6V 0V 5 6V 1 3K 4 GND n a n a n a n a 5 GND n a n a n a n a 6 GND n a n a n a n a 7 10V 0V 10 5V 2 7K 8 GND n a n a n a n a 9 16V 0V 16V 12 3K 1...

Page 6: ... 2 6K 4 PoWERoFF 0V 0V 2 8K 5 ACCLoCK 3 3V 3 8V 11 1K 6 PoWER1 0V 4 8V 9 6K 7 PoWER2 0V 3 1V 10 5K 8 N C n a 3 3V 9 1K n a CNPPS to Digi Main PPM2 Pin Label SBY RUN Ohm Out In 1 5 6V 0V 5 6V 1 3K 2 5 6V 0V 5 6V 1 3K 3 5 6V 0V 5 6V 1 3K 4 GND n a n a n a n a 5 GND n a n a n a n a 6 GND n a n a n a n a 7 10V 0V 10V 2 7K 8 GND n a n a n a n a 9 16V 0V 16V 12 3K 10 GND n a n a n a n a 11 GND n a n a n...

Page 7: ...n 1 5 6V 0V 5 6V 1 3K 2 5 6V 0V 5 6V 1 3K 3 5 6V 0V 5 6V 1 3K 4 GND n a n a n a n a 5 GND n a n a n a n a 6 GND n a n a n a n a 7 10 5V 0V 10V 2 7K 8 GND n a n a n a n a 9 16V 0V 16V 12 3K 10 GND n a n a n a n a 11 GND n a n a n a n a 12 GND n a n a n a n a 13 15V 0V 10 6V 3 2K 14 15V 0V 10 6V 3 2K 15 15V 0V 10 6V 3 2K 1 Va 0V 65 1V 13 6K 2 N C n a n a n a 3 Vcc 0V 5 1V 0 7K 4 GND n a n a n a n a ...

Page 8: ...el SBY RUN Ohm Out In 1 STBY 5 0V 5 2V 5 2V 1 9K 2 GND n a n a n a n a 3 STBY 3 3V 3 3V 3 3V 2 6K 4 PoWERoFF 0V 0V 2 8K 5 ACCLoCK 3 3V 3 8V 11 1K 6 PoWER1 0V 4 8V 9 6K 7 PoWER2 0V 3 1V 10 5K 8 N C n a 3 3V 9 1K n a CNPPS to Digi Main PPM2 Pin Label SBY RUN Ohm Out In 1 5 6V 0V 5 6V 1 3K 2 5 6V 0V 5 6V 1 3K 3 5 6V 0V 5 6V 1 3K 4 GND n a n a n a n a 5 GND n a n a n a n a 6 GND n a n a n a n a 7 10V ...

Page 9: ...ng correctly first For Procedure Please visit our web site On our web site see these models Things You Should Know section Power Supply Issues to download these documents DW 3 Power Supply Explanation pdf http www hitachiserviceusa com service Seminars Plasma Web DW3 Web Fixes 00 Things Known htm If the Power Supplies is working OK then go back to page 3 and see If the Answer is 2 Follow the proce...

Page 10: ...ago or Vcego will never attempt to turn on Vs Va again If AC is remove this will reset the Power Supply but it takes over 5 minutes 9 The Power Supply can be forced On 2 procedures to test all power supplies First One Procedure to test all voltage but Vs Va and Vcc 5 1V Also Vs 42 Second One Procedure to test Vs Va and Vcc 5 1V voltages This procedure requires the First process to be active Also V...