English
12
3.
Charging
䡬
When the battery is connected to the battery
charger, charging will commence and the charge
status lamp will light in red. (See Table 2)
NOTE:
If the charge status lamp flikers in red, pull out the
plug from the receptacle and check if the battery
is properly mounted.
Before
charging
While
charging
Charging
complete
Charging
impossible
Overheat
standby
Malfunction in the
battery or the charger
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
Table 2
Blinks
(RED)
Lights
(RED)
Blinks
(RED)
Flickers
(RED)
Lights
(GREEN)
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1
seconds. (off for 0.1 seconds)
Lights continuously
Charge
status
lamp (RED)
Overheat
lamp
(GREEN)
NOTE:
When standby for cooling battery, UC36YRL cools the overheated battery by cooling fan.
Indications of the lamp
䡬
Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are
as shown in the table below, and batteries that
have become hot should be cooled for a while
before being recharged.
䡬
Regarding recharging time
Table 4 shows the recharging time required
according to the type of battery.
NOTE:
The recharging time may vary according to the
ambient temperature.
4.
Disconnect battery charger from the receptacle.
CAUTION:
Do not pull the plug out of the receptacle by pulling
on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
5.
Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out
the battery from the battery charger.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an
extended period is not activated, the electric
discharge might be low when using them the first
and second time. This is a temporary
phenomenon, and normal time required for
recharging will be restored by recharging the
batteries 2 – 3 times.
Table 3
Rechargeable
Temperatures at which the
batteries
battery can be recharged
BSL2530
32°F — 122°F (0°C — 50°C)
䡬
When the battery is fully charged, the charge status
lamp will bilink in red slowly. (At 1-second
intervals) (See Table 2)
Battery capacity (Ah)
Li-ion BATTERY
3.0 Ah
25.2V
BSL2530
60min.
Battery
Voltage
Table 4 Recharging time (approx. min.) at 20°C
01Eng_DH25DAL_US
9/14/07, 20:39
12