8-5. Insulation Tests
On completion of reassembly after repair, measure the insulation resistance and conduct the dielectric strength
test.
Insulation resistance: 7 M
Ω
or more with DC 500 V Megohm Tester
Dielectric strength: AC 2500 V/1minute, with no abnormalities
8-6. No-Load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage (V)
3.0
Current (A) Max.
120