Menu items
View/description
Value/view/reference
Shield State Supported Status of diagnostics for
physical drives of the disk
array controller
Yes
NVSRAM Size (MB)
NVSRAM Size
32
Metadata Size (MB)
Metadata Size
512
Minimum Strip Size
Minimum Strip Size
64 KB
Maximum Strip Size
Maximum Strip Size
64 KB
CacheCade – SSD
Caching
CacheCade setting
Disabled
Write Cache Capable
Write Cache setting
No
Configured Cache Size
(GB)
Current cache size (GB)
0
Maximum Allowed
Cache Size
(GB)
Maximum Allowed Cache Size
(GB)
0
Replace Drive
Copyback
Enabled (valid) /
[<<Disabled (invalid)>>]
Replace Drive on
SMART Error
SMART copyback
Enabled (valid) /
[<<Disabled (invalid)>>]
Rebuild Rate
Priority of rebuilding process
0 to 100 / [<<30>>]
Background
Initialization
(BGI) Rate
Priority of background
initialization
0 to 100 / [<<30>>]
Consistency Check Rate Priority of consistency check
0 to 100 / [<<30>>]
Reconstruction Rate
Priority of capacity expansion 0 to 100 / [<<30>>]
Controller BIOS
Disk array controller BIOS is
enabled.
[<<Enabled (valid)>>] /
Disabled (invalid)
Coercion Mode
Set a physical hard disk in
creating virtual drives
[<<None (All capacity
used)>>] / 128 MB
(Multiples of 128 MB
used) / 1GB (Multiples of 1
GB used)
SMART Polling
Sets an interval of SMART
polling
0 to 65535/ [<<600>>]
Alarm Control
Sounds the disk array
controller buzzer when a
connected device fails.
Enabled (valid) /
[<<Disabled (invalid)>>]
Boot Error Handling
Error notice of the disk array
controller at the system boot
Safe mode (Boot in safe
mode) / [Ignoreerrors
(Ignores the error to
continue running)]
(Recommendable value
without using SAS 3004
SAS 3004 iMR ROMB Configuration Utility
5-23
Hitachi Compute Blade 500 Series EFI User's Guide
Summary of Contents for Compute Blade 500 Series
Page 8: ...viii Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 14: ...xiv Preface Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 445: ...SAS configuration utility 7 11 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 468: ...7 34 SAS configuration utility Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 475: ...BIOS settings for PXE boot 8 7 Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 476: ...8 8 BIOS settings for PXE boot Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 504: ...10 12 Fibre channel over Ethernet FCoE Hitachi Compute Blade 500 Series EFI User s Guide ...
Page 505: ...Hitachi Compute Blade 500 Series EFI User s Guide ...