A guideline of expanding time is shown in the following table.
Table 4-19 Guideline of initialization
RAID level
Capacity of a disk array
Rebuilding time for expansion
RAID 0
900GB (SAS: 300GB HDD x 3)
Approximately 210 minutes
600GB (SAS: 200GB SSD x 3)
Approximately 70 minutes
RAID 5
600GB (SAS: 300GB HDD x 3)
Approximately 160 minutes
400GB (SAS: 200GB SSD x 3)
Approximately 60 minutes
RAID 6
600GB (SAS: 300GB HDD x 4)
Approximately 170 minutes
400GB (SAS: 200GB SSD x 4)"
Approximately 60 minutes
Tip: The rebuilding time for expansion is proportional to the capacity of a
disk array regardless of the number of hard disks to add.
8
.
When rebuilding is completed to 100%, click Home.
4-76
MegaRAID WebBIOS for storage expansion blades
Hitachi Compute Blade 500 Series EFI User's Guide