5.2 Logging in to the unit after powering it on for the first
time
When you start the unit for the first time, you need to log in using the default user information shown in the table
below and then change the password.
Table 5‒1: Default user information
User name
Password
Description
edgeadm
Hitachi1
This password is only valid for the first login.
You must change the password at the first login.
#
Manage the new password so that you will not forget
it.
#:
To ensure security, the password change function starts immediately after the first login.
Note that, when repair work is performed, the operating system might be reinstalled. In that case, the password
and other settings will be initialized.
Set a new password for
edgeadm
. Use the new password for the subsequent login.
Login: edgeadm
Password: Hitachi1
You are required to change your password immediately (root enforced)
Changing password for edgeadm.
(current) UNIX password: <- Enter "Hitachi1" for the password.
New password: <- Enter the new password.
Retype new password: <- Enter the new password again for the confirmation
In addition, consider creating a user account for each person who operates the unit, such as for each maintenance
worker, rather than allowing
edgeadm
to be shared by multiple users. Setting an account for each user makes it easier
to identify the cause of a security incident.
For details about how to add or delete a user or change the password, see 6. Managing User Accounts.
After the password is set, the software license is displayed. Verify the displayed information, enter
yes
, and then
press the
Enter
key.
Depending on the software installed on the product, multiple licenses might be displayed. If you verify all the licenses
and then enter
yes
, you will be logged in to the unit.
5. Configuring Software Environment
31
Summary of Contents for CE50-10
Page 1: ...Hitachi Industrial Edge Computer CE50 10 Instruction Manual CC 65 0171 ...
Page 10: ......
Page 23: ...Figure 1 6 Attaching mounting brackets 4 1 Installing the CE50 10 7 ...
Page 26: ......
Page 38: ......
Page 42: ...4 2 5 Connection diagram Figure 4 2 Connection diagram 4 External Contact Functions 26 ...
Page 44: ......
Page 87: ... sudo etc init d netfilter persistent save 5 Configuring Software Environment 71 ...
Page 117: ...version information 13 Log out from the unit exit 5 Configuring Software Environment 101 ...
Page 148: ......
Page 149: ...7 Maintaining the CE50 10 This chapter describes maintenance of the CE50 10 133 ...
Page 157: ...8 Troubleshooting This chapter describes troubleshooting of the CE50 10 141 ...
Page 162: ...8 1 14 Cannot turn off the power to the unit Please contact us 8 Troubleshooting 146 ...