17–8
Troubleshooting
Hitachi Unified Storage Hardware Service Guide
Storage system failures
A storage system failure may have occurred if one or more of the following
conditions occurs:
• The storage system sends an email alerting you to a failure.
• The Alarm or Warning LED on the front panel goes ON.
• The Ready LED on the front panel is OFF.
• You experience performance deterioration with the storage system.
• A VOL cannot be recognized.
• A host cannot see a data port on the storage system.
If one or more of these actions occurs, perform the following steps to
recover from the failure:
1. Log in to Storage Navigator Modular 2:
2. Go to the Explorer pane and click Arrays.
3. In the Arrays area, check the status and serial number of the storage
system where the failure occurred.
4. If you received an email message about the failure, check that the
hardware serial number in the email matches the one on the storage
system.
5. Check the status column of the system that matches the hardware serial
number checked in the previous step.
• Normal = The storage system is operating normally. The fault may
have occurred between the storage system and the host. See “Host
cannot access storage” in
• --- = Storage Navigator Modular 2 cannot access the storage
system. The main switch may be set to the OFF position or a
network failure may have occurred between the host and the
storage system.See
Hitachi Storage Navigator Modular 2 cannot
connect to storage system on page 17-4
.
6. From the Arrays page, click the name of the storage system. When the
next screen appears, click either Alerts & Events in the Arrays pane or
Check for Errors in the Common Array Tasks area. In the Alert Parts
tab, check for the failed part, such as a disk drive.
NOTE: If Storage Navigator Modular 2 does not start:
• A communication failure with the Storage Navigator Modular 2 server
may have occurred or the Storage Navigator Modular 2 server may not
be started normally. See the “Storage Navigator Modular 2 will not
start” topic in
.
• The storage system may be turned off or there may be a network
failure between Storage Navigator Modular 2 and the storage system.
See the “Storage Navigator Modular 2 cannot communicate with the
storage system” topic in
Summary of Contents for CBL
Page 20: ...xx Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS ...
Page 30: ...xxx Hitachi Unified Storage Hardware Service Guide CBL CBLE CBLD DBS DBSD DBL DBLD DBF ...
Page 39: ...xxxix Hitachi Unified Storage Hardware Service Guide Out ...
Page 40: ...xl Hitachi Unified Storage Hardware Service Guide ...
Page 152: ...5 8 Replacing a cache backup battery Hitachi Unified Storage Hardware Service Guide ...
Page 156: ...6 4 Replacing a Fan Module Hitachi Unified Storage Hardware Service Guide ...
Page 180: ...8 16 Adding and replacing controllers Hitachi Unified Storage Hardware Service Guide ...
Page 188: ...9 8 Replacing cache memory Hitachi Unified Storage Hardware Service Guide ...
Page 200: ...11 6 Replacing the Host connector Hitachi Unified Storage Hardware Service Guide ...
Page 204: ...12 4 Replacing the Drive I O Module Hitachi Unified Storage Hardware Service Guide ...
Page 212: ...14 4 Replacing the SAS ENC cable Hitachi Unified Storage Hardware Service Guide ...
Page 274: ...17 14 Troubleshooting Hitachi Unified Storage Hardware Service Guide ...
Page 291: ...1 Hitachi Unified Storage Hardware Service Guide ...