Table 1-20 Example for CB 520A A1 when Onboard LAN Card is not
installed (Emulex 10Gb 4ports)
Physical NIC
Physical Port
No.
1
Logical Port
No.
2
Detection No.
of LAN
controller
Network
segment
Mezzanine Card
1
(Emulex 10Gb
4ports)
0
2
2
2av
1
3
2bv
2
0
1
1av
3
1
1bv
Notes:
1
.
The physical port number which exists on the system.
2
.
The logical port number which displays on the LPAR manager screen.
Table 1-21 Example for CB 540A A1/B1, CB 520X B1/B2/B3 when Onboard
LAN Card is not installed (Emulex 10Gb 4ports)
Physical NIC
Physical Port No.
1
Logical
Port No.
2
Detection No. of
LAN controller
Network
segment
Mezzanine Card 1
(Emulex 10Gb
4ports)
0
0
1
1av
1
1
1bv
2
2
2
2av
3
3
2bv
Mezzanine Card 3
(Emulex 10Gb
4ports)
3
0
0
3
3av
1
1
3bv
2
2
4
4av
3
3
4bv
Notes:
1
.
The physical port number which exists on the system.
2
.
The logical port number which displays on the LPAR manager screen.
3
.
NIC cannot be installed on Mezzanine Card 3 for CB 520X B1.
1-30
LPAR manager Functions