--- 28 ---
Type of
crown molding
To process crown molding at
positions and in Fig. 39
To process crown molding at
positions and in Fig. 39
Miter angle
setting
Bevel angle
setting
Miter angle
setting
Bevel angle
setting
Right 30˚
( mark)
Right 35.3˚
( mark)
Left 30˚
( mark)
Right 30˚
( mark)
Left 35.3˚
( mark)
Left 30˚
( mark)
For miter cut setting
If the turn table has been set to either of the angles described, move the turn table adjusting side handle a little
to the right and left to stabilize the position and to properly align the miter scale and the tip of the indicator
before the operation starts.
For bevel cut setting
Move handle on miter section to the right and left and check that the position is stable and the angle scale and
the tip of the indicator are properly aligned. Then tighten the clamp lever.
45˚ type
Right 31.6˚
( mark)
Left 33.9˚
( mark)
Right 33.9˚
( mark)
Left 31.6˚
( mark)
Left 33.9˚
( mark)
38˚ type
3
1
4
2
Right 33.9˚
( mark)
Table 10
(1) Setting to cut crown molding at positions and in Fig. 39 (See Fig. 41, tilt the head to the left.):
Turn the turn table to the right and set the miter angle as follows:
For 45˚ type crown moldings: 35.3˚ ( mark)
For 38˚ type crown moldings: 31.6˚ ( mark)
Turn the head to the left and set the bevel angle as follows:
For 45˚ type crown moldings: 30˚ ( mark)
For 38˚ type crown moldings: 33.9˚ ( mark)
Position the crown molding so that the lower surface ( in Fig. 38) contacts the fence as indicated in
Fig. 42.
1
4
2
3
A
30˚ and 33.9˚ left slant setting method
Loosen the clamp lever and slant to the left a little at a time while
pushing the fixing pin into the main unit. At this time, the fixing
pin will enter one step and fit into the 30˚ left slant and 33.9˚ left
slant slots.
With the fixing pin in the slot as described above, setting to the
30˚ left slant position is possible by pushing to the right side.
Also, with the fixing pin in the slot as described above, setting to
the 33.9˚ left slant position is possible by pushing to the left side.
Look at the bevel scale and indicator to recheck whether or not
the settings match and then tighten the clamp lever.
2
3
1
1
4
Fixing pin
Loosen
Tighten
Clamp lever
Holder (A)
Bevel scale
Indicator
(for left bevel scale)
Push
Fig. 40