3. General data
TCGB0075 rev.0 - 11/2012
59
3
3.3 Indoor unit
3.3.1 RWH-(4.0-6.0)FSVNFE
Model
RWH-4.0FSVNFE
RWH-5.0FSVNFE
RWH-6.0FSVNFE
Electrical power supply
-
1~ 230V 50Hz
Pump input power
W
140
140
140
Maximum current
A
24.0
28.0
31.0
Nominal water flow (condition
)
m³/h
1.7
2.1
2.4
Unit
dimensions
Height
mm
706 (*1)
Width
mm
595
Depth
mm
695
Packaging
dimensions
Height
mm
837
Width
mm
770
Depth
mm
720
Net weight
kg
157
162
162
Packaging dimensions
m³
0.46
Refrigerant
-
R-134a
Flow control
-
Microprocessor-controlled expansion valve
Compressor type
-
DC inverter driven hermetic scroll
Quantity
-
1
1
1
Power
kW
3.0
3.0
3.0
Refrigerant charge
kg
2.5
Refrigerant pipe connection
-
Flare nut connection (*2)
Dimensions
Liquid pipe
mm
Ø 9.53 (3/8”)
Gas pipe
mm
Ø 15.88 (5/8”)
Water pipe connection
-
Screwed connections
Space
heating
Inlet diameter
inch
Flexible pipe (G 1” male)
Outlet diameter
inch
Flexible pipe (G 1” male)
DHW
Inlet diameter
inch
Flexible pipe (G 3/4” male)
Outlet diameter
inch
Flexible pipe (G 3/4” male)
Expansion vessel volume
l
12
Color
-
White (RAL 9016)
N O T E
•
(*1): Dimensions with the minimum mounting foot height. This value can be adjusted up to +30 mm.
• (*2): Refrigerant liquid/gas piping accessory is factory-supplied in order to assist in the refrigerant pipe con
-
nection. In this case the connection to the field refrigerant pipe must be brazed. For more information, please
refer to the Installation and operation manual.