background image

1. Mounting of locks in door frame

The lock is mounted in the frame in the mounting holes    . 
The holes are drilled and threaded as shown below. We 
recommend you to use one of our adapter plates when re-

placing a lock with different hole pattern.

2. Adjustment of lock engagement and clearance

The door lock should be adjusted so that the latching bolt engage-
ment is 15 mm. According to standard EN81-20, the minimum per-
missible locking is 7 mm + movement with closed contact (approx. 
2 mm). The locking engagement is adjusted by moving the lock in 
the holes 1 (see Figure 1).
The lock is adjusted so that there is clearance at the latching bolt and 
the door leaf in  locked position. We recommend a clearance of 1-2 
mm. If necessary, washer/distance bush can be placed between the 
lock and the frame if the clearance is too large.

Figure 2 

Approved positions

LO-30

Door lock LI-25

Reference

Installation instruction LI- 25

LI-25-H (right) and LI-25-V (left) are maintenance-free 
freight lift locks for double swing doors.
The LI-25 comes with 1pc mounted KL-30 lock contact and  
LI-25-H & V both uses KO-26 door contacts included in Kit.

Contents of packaging

1. Door lock
2. Pull rod
3. Linkage arm (LI-25)
4. Lock roller with shaft
5. KO-26 door contacts (2pcs)
6. Suitable contact bridges

Recommended tools

Screwdriver – Torx 20

Required material 

2 screws M8x12mm with suitable washers.

I N S T A L L A T I O N   I N S T R U C T I O N

1 OF 2

Figure 1

 

Distance between mounting holes

LI-25

Figure 3 

Locking engagement and clearance viewed from the bottom of the lock

Picture showing right variant lock

1

3. Emergency opening function 

i. Valid only to locks with triangle opening

Holes are drilled in the door frame for the emergency 

opening function as shown in the figure below. The 

hole should be at least 14mm in diameter and the tri-
angle should be recessed at least 3mm from the front 
to meet the EN81-20 standard.

Figure 4 (i) 

Emergency unlocking

Reviews: