background image

Installation Instructions

KB-M2-WMT- _ _ , KB-R2-WMT- _ _ , and KB-R3-WMT- _ _ Series

Wall Mount Folding Keyboard

76.2 mm

(3.00")

450.85 mm

(17.75")

+ 2.3 mm (0.09")

- 0.8 mm (0.03")

38.1 mm

(1.50")

Ø

Ø

8 mm (5/16") DIAMETER

OR 1/4-20 TAPPED HOLES

(PREFERRED FOR EASIER

INSTALLATION) (8 PLACES)

PLACE 44" OFF FLOOR

FOR MOST UNIVERSAL

ERGONOMIC HEIGHT

25.4 mm

(1.00")

31.8 mm

(1.25")

11.1 mm

(0.438")

31.8 mm

(1.25")

FIGURE 1 – PANEL MOUNTING PATTERN

1.  Cut or drill mounting pattern in panel using the provided cutout template.  Refer to Figure 1 for the panel mounting 

pattern.

NOTE:  +/- 0.8 mm (0.03") tolerance on all dimensions unless otherwise noted

The provided hardware is for use with panels that have a maximum thickness of 6.4 mm (1/4") if using 

clearance holes.  Thicker panels can be used but require 1/4-20 tapped holes or longer screws than 

those provided.  For thicker panels or panels where rear access requires a second person, you must 

install the plastic bulkhead fitting onto the left hand wall bracket first (as shown in steps 7 and 8), and 

then proceed from step 1.

RUBBER WASHER

GASKET

NUT

NYLON WASHER

1/4-20 SCREWS

LEFT HAND WALL BRACKET

1/4-20 SCREWS

FIGURE 2 – SIDE VIEW AND FRONT VIEW OF LEFT HAND WALL BRACKET

2. 

Install the left hand wall bracket first using four of the provided 1/4-20 screws, washers, and nuts as shown.  Tighten 

all screws until the gasket is compressed to 1/16" to 3/32" thick.

99109A 

 December 16, 2019 

 www.HopeIndustrial.com 

 

International: 

+1 (678) 762-9790 

• UK: 

+44 (0) 20 7193 2618 

 © 2020 Hope Industrial Systems, Inc. 

 Page 1 of 4

Summary of Contents for KB-M2-WMT Series

Page 1: ... that have a maximum thickness of 6 4 mm 1 4 if using clearance holes Thicker panels can be used but require 1 4 20 tapped holes or longer screws than those provided For thicker panels or panels where rear access requires a second person you must install the plastic bulkhead fitting onto the left hand wall bracket first as shown in steps 7 and 8 and then proceed from step 1 RUBBER WASHER GASKET NU...

Page 2: ...E 3 FRONT VIEW AND SIDE VIEW OF RIGHT HAND WALL BRACKET Wall Mount Folding Keyboard Installation Instructions continued CABLE FIGURE 4 FRONT VIEW SHOWING KEYBOARD 4 Slide the keyboard cable through the slot on the left hand wall bracket as shown IMPORTANT THEKEYBOARDMUSTBESUPPORTEDSOTHATNOPRESSUREORWEIGHTISAPPLIEDTOTHECABLE ITSELF DURING THE INSTALLATION PROCESS 99109A December16 2019 www HopeIndu...

Page 3: ...g the right hand wall bracket using the remaining three 1 4 20 screws washers and nuts Tighten all screws until the gasket is compressed to 1 16 to 3 32 thick 7 Unscrew the first nut from the plastic bulkhead fitting on the keyboard cable and remove from the end of the cable FIGURE 7 FRONT VIEW NUT PLASTIC BULKHEAD FITTING 99109A December16 2019 www HopeIndustrial com International 1 678 762 9790 ...

Page 4: ...P AND FRONT VIEWS CABLE NUT PANEL FIGURE 9 TOP AND FRONT VIEWS CABLE CABLE GLAND NUT IMPORTANT FAILURETOFULLYTIGHTENEITHERNUTWILLCOMPROMISETHEWATERTIGHTSEALONTHEPANEL FIGURE 10 SIDE VIEW SHOWING 4 POSITIONS KEYBOARD HAS 4 POSITIONS LOCK UP TYPE UP FLAT TYPE DOWN LOCK DOWN LIFT TO DISENGAGE FROM LOCK UP POSITION PULL TO DISENGAGE FROM LOCK DOWN POSITION 99109A December16 2019 www HopeIndustrial com...

Reviews: