Installation Instructions
KB-M2-WMT- _ _ , KB-R2-WMT- _ _ , and KB-R3-WMT- _ _ Series
Wall Mount Folding Keyboard
76.2 mm
(3.00")
450.85 mm
(17.75")
+ 2.3 mm (0.09")
- 0.8 mm (0.03")
38.1 mm
(1.50")
Ø
Ø
8 mm (5/16") DIAMETER
OR 1/4-20 TAPPED HOLES
(PREFERRED FOR EASIER
INSTALLATION) (8 PLACES)
PLACE 44" OFF FLOOR
FOR MOST UNIVERSAL
ERGONOMIC HEIGHT
25.4 mm
(1.00")
31.8 mm
(1.25")
11.1 mm
(0.438")
31.8 mm
(1.25")
FIGURE 1 – PANEL MOUNTING PATTERN
1. Cut or drill mounting pattern in panel using the provided cutout template. Refer to Figure 1 for the panel mounting
pattern.
NOTE: +/- 0.8 mm (0.03") tolerance on all dimensions unless otherwise noted
The provided hardware is for use with panels that have a maximum thickness of 6.4 mm (1/4") if using
clearance holes. Thicker panels can be used but require 1/4-20 tapped holes or longer screws than
those provided. For thicker panels or panels where rear access requires a second person, you must
install the plastic bulkhead fitting onto the left hand wall bracket first (as shown in steps 7 and 8), and
then proceed from step 1.
RUBBER WASHER
GASKET
NUT
NYLON WASHER
1/4-20 SCREWS
LEFT HAND WALL BRACKET
1/4-20 SCREWS
FIGURE 2 – SIDE VIEW AND FRONT VIEW OF LEFT HAND WALL BRACKET
2.
Install the left hand wall bracket first using four of the provided 1/4-20 screws, washers, and nuts as shown. Tighten
all screws until the gasket is compressed to 1/16" to 3/32" thick.