24
Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015
The input voltage is electrically isolated from the housing.
You have the option of supplying the supply voltage redundantly, without
load distribution.
Use a power supply cable which is suitable for the voltage, the current and
the physical load.
Hirschmann recommends a wire diameter of 0.75 mm² to 1.0 mm²
(AWG18 to AWG16).
The supply voltage is connected via a 5-pin 7/8" connector.
Connect the power supply cables.
2.2.3
Devices featuring supply voltage with the
characteristic value N
The input voltage is electrically isolated from the housing.
The supply voltage is connected via a 4-pin 7/8" connector.
Use a power supply cable which is suitable for the voltage, the current and
the physical load.
Hirschmann recommends a wire diameter of 0.75 mm² (AWG18).
Type and specification of the supply
voltage
Rated voltage range DC
24 V ... 48 V
Voltage range DC incl. maximum tolerances 16,8 V ... 60 V
Figure
Pin
Function
1
+ 24 ... 48 V DC (1)
2
0 V (1)
3
Not used
4
0 V (2)
5
+ 24 ... 48 V DC (2)
Table 6:
Pin assignment of the 5-pin 7/8" connector for connecting the supply
voltage
Type and specification of the supply
voltage
Rated voltage range DC
72 V ... 110 V
Voltage range DC incl. maximum tolerances 50,4 V ... 138 V
P2−
P2+
P1+
P1−
N.C.