Installation OCTOPUS OS20/OS24 Unmanaged
Release 08 07/2015
23
The input voltage is electrically isolated from the housing.
You have the option of supplying the supply voltage redundantly, without
load distribution.
Use a power supply cable which is suitable for the voltage, the current and
the physical load.
Hirschmann recommends a wire diameter of 0.5 mm² to 0.75 mm²
(AWG20 to AWG18).
The supply voltage is connected via a 5-pin M12 connector (A coding, e.g.
ELWIKA 5012 PG7 from Hirschmann, supplied).
Connect the power supply cables.
2.2.2
Devices featuring supply voltage with the
characteristic value F
Type and specification of the supply
voltage
Rated voltage range DC
24 V ... 48 V
Voltage range DC incl. maximum tolerances 9,6 V ... 60 V
Figure
Pin
Function
1
+ 24 ... 48 V DC (1)
2
Not used
3
0 V
4
+ 24 ... 48 V DC (2)
5
Not used
Table 5:
Pin assignment of the 5-pin M12 socket for connecting the supply voltage
WARNING
ELECTRIC SHOCK
The nominal voltage of 48 V specified for trains can temporarily exceed the
SELV threshold of 60 V based on EN 50155 para. 5.1.1.1. Use additional
measures to limit the surge voltage to 60 V or use a lower nominal voltage.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.