Synchronizing the System Time of the
88
7.2 SNTP
Layer 2 Enhanced with Layer 2 Professional
Release 1.0 10/05
7.2.3 Configuring SNTP
V
Select the
Time:SNTP
dialog.
U
Configuration SNTP Client and Server
V
In this frame you Switch the SNTP function on/off.
When it is switched off,
the SNTP server does not send any SNTP packages and does
not reply to any SNTP requests.
The SNTP client does not send any SNTP requests and does not
interpret any broadcast/multicast packages.
U
SNTP-Status
D
The “Status message” displays conditions such as “Server cannot
be reached”.
U
Configuration SNTP Server
V
In “Anycast destination address” you enter the IP address to
which the SNTP server on the Switch sends the SNTP packages.
IP target address
Send SNTP
packages periodically
to
0.0.0.0
Nobody
Unicast
Unicast
224.0.1.1
Multicast
255.255.255.255
Broadcast
Table 4: Periodic sending of SNTP packages
V
In “VLAN ID” you specify the VLAN to which the Switch may
periodically send SNTP packages.
V
In “Anycast send interval” you specify the interval at which the
Switch sends SNTP packages (valid entries: 1 second to 3600 se-
conds, default: 120 seconds).
Summary of Contents for MS30, Power MICE, MACH 4000, OCTOPUS
Page 8: ...Contents 8 Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Page 10: ...About this Manual 10 Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Page 14: ...Introduction 14 Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Page 194: ...188 Index Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Page 195: ......
Page 196: ......