![Hirschmann MS30, Power MICE, MACH 4000, OCTOPUS User Manual Download Page 40](http://html1.mh-extra.com/html/hirschmann/ms30-power-mice-mach-4000-octopus/ms30-power-mice-mach-4000-octopus_user-manual_2138036040.webp)
Entering the IP parameters
40
2.5 System configuration via BOOTP
Layer 2 Enhanced with Layer 2 Professional
Release 1.0 10/05
rs2_01:ht=ether-
net:ha=008063086501:ip=149.218.17.83:tc=.global:
rs2_02:ht=ether-
net:ha=008063086502:ip=149.218.17.84:tc=.global:
.
.
Lines that start with a '#' character are comment lines.
The lines under “.global:” make the configuration of several devices easier.
With the template (tc) you allocate the global configuration data (tc=.global:).
The direct allocation of hardware address and IP address occurs in the de-
vice lines (rs2-0...).
V
Enter one line for each device.
V
After
ha=
enter the hardware address of the device.
V
After
ip=
enter the IP address of the device.
Refer to
“Setting up DHCP/BOOTP Server” on page 154
DHCP server configuration example.