background image

1. Disconnect the IRD 8500/.. from the mains.

2. Loose the screws on the cover and remove it.

3. Replace the empty lithium battery by a new one (lithium battery CR 2477N 3V/

1000mAh; Manufacturer: RENATA)

4. Watch out for the correct polarity of the battery !

5. Close the cover.

6. Reconnect the device to the mains.

7. Carry out a functional check ( see chapter ).

Maintenance

IRD 8500/..

4 - 6

Intergrated Receiver Decoder

1

Lithium Batterie 3V
lithium battery 3V

Explosionsgefahr bei
unsachgemäßem Austausch
der Batterie.
Explosion risk by improper
replacement of battery.

Top view of Integrated Receiver Decoder with open cover (only CPU board)

Summary of Contents for IRD 8500

Page 1: ...Print 1 0 Issue October 2000 BH_8450E IRD 8500 Operating manual Integrated Receiver Decoder...

Page 2: ...efinitions 1 7 Putting into operation 2 1 Description 2 2 General 2 2 Design 2 2 Power supply 2 3 Control 2 3 Monitoring 2 3 SAT receiver demodulator 2 4 MPEG processing 2 5 Conditional Access Option...

Page 3: ...et Reset 3 7 Network 3 7 Display 3 9 Date Time Temperature 3 9 PIN Code 3 9 Maintenance 4 1 Important notes 4 2 Functional check 4 3 Procedure 4 3 Nominal operation state 4 3 Help with problems 4 4 Ch...

Page 4: ...mains connection 4 9 Ordering information Integrated Receiver Decoder for 115 V mains connection 4 9 Ordering information for options 4 9 Services 4 10 Changes 5 1 Appendix 6 1 General data 6 2 Techn...

Page 5: ...or translated into another language without the prior written consent of Hirschmann Explanation of warning and note symbols WARNING Indicates that ignorance or neglicence of the recommended cautionar...

Page 6: ...connected only to grounded mains ATTENTION The mains cable must not be exposed to mechanical stress ATTENTION The mains cable must be disconnected from the IRD 8500 if the cable or the plug was damag...

Page 7: ...a certain amount of bit errors can be corrected on the receiver side The procedures for coding and transmission are defined by the European DVP project MPEG 2 The MPEG 2 standard ISO IEC 13818 set up...

Page 8: ...from the demultiplexer to the decoder Decoding The encoding of the received data can take place on various levels The entire transport stream or elementary streams Packetized Elementary Streams PES ca...

Page 9: ...Table an electronic TV guide with identification of programme start and age classification RST Running Status Table contains status information about the individual programmes TDT Time and Date Table...

Page 10: ...into a transportstream acc to time multiplex for MPEG2 Packetgeneration A single PES contains the video audio and data information of a single programme The length of the transmitted packets are 188...

Page 11: ...ditional Access Module The CA module is used for decoding encoded programmes CA Conditional Access Several providers send their programmes encoded In order to de code this programmes on the receiver s...

Page 12: ...availa ble With option LNB supply the supply voltage 13 18V and the control signal 22kHz are available Design View The IRD 8500 is built as a 19 slide in module with 1HU height The front panel contai...

Page 13: ...face A stan dard WWW browser with TCP IP protocol e g Internet Explorer is to be used The remote control can be disabled on the IRD 8500 Monitoring General For monitoring there are the following possi...

Page 14: ...ransport streams are displayed Unique identification of a transport stream is only possible with the TS ID The displayed input frequency of a transport stream can vary about the frequency de viation o...

Page 15: ...demultiplexer is synchronized with the MPEG input data stream sync ok is dis played If the decoder can decode the signal correctly play is displayed otherwise idle is displayed Monitoring of the corr...

Page 16: ...e set in 3 diffe rent ways l pass through not defined output image l letter box vertical filter black bar on the upper and lower image margin l pan scan expanding to the total image height trimming th...

Page 17: ...wing possibilities Menu Audio Mode l Mono l Stereo l 2 Tone R l 2 Tone L The selection of the audio baseband signal does not influence the sound coding mono stereo 2tone carried out by the MPEG input...

Page 18: ...Encoder FPGA MPEG Decoder MPEG Demux Data Latch Data Latch Common Interface CI SAT Demodulator Option MPEG Interface mC to Conditional Access Module MPEG SPI input MPEG SPI ASI output TTX OUT LCD Key...

Page 19: ...lights up red in case of an alarm or hardware error In addition the dis play shows which error occured e g ERROR sync nok 7 Slide in place for Conditional Access Module 8 AUDIO monitoring output AUDI...

Page 20: ...ut SPI e 25 pole sub D socket 9 remote monitoring interface ALARMS 9 pole sub D socket 10 RS 232 interface 9 pole sub D socket 11 10 Mbit Ethernet interface 10BASE T RJ 45 Stuart connector 12 LED LINK...

Page 21: ...C or 42 VAC SELV acc to EN60950 Maximal switchable current 0 5 A SELV low voltage circuit safety extra low voltage Pin Remark 1 break contact alarm 2 base contact alarm or warning 3 make contact warni...

Page 22: ...et interface is using a RJ 45 Stuart connector Pin Remark 1 RD Receive data positive 2 RD Receive data negative 3 TD Transmit data positive 6 TD Transmit data negative 4 5 7 8 not used Putting into op...

Page 23: ...fore operation read the chapter Menu operation Procedure 1 Check if the supply voltage shown beside the mains socket matches the mains voltage ATTENTION A wrong mains voltage will cause a defect in th...

Page 24: ...he transport stream l Select service selection of the program l Select language selection of sound2 With finished you return to the main menu The IRD 8500 is now ready for ope ration 9 Check the LED s...

Page 25: ...Network setting and query of the network parameters l Miscellaneous query of device configuration entry of PIN codes Menu tree Menu operation IRD 8500 3 2 Intergrated Receiver Decoder MPEG processing...

Page 26: ...0 Intergrated Receiver Decoder 3 3 Status History Network Miscellaneous Device status History show History delete Extended messages Network access Remote control Online users Ethernet status Ethernet...

Page 27: ...on menu in the following way l to confirm the entry press the ENTER key l to cancel the entry press the ESC key l to exit the menu press the ESC key or the key l If a value is changed a range window s...

Page 28: ...an be selected and changed see change settings Confirmation of the entries with the ENTER key Password protection Menu Change password You can provide the IRD 8500 with a password protection At delive...

Page 29: ...sy l SG Nr Software version of the assy l Prod Date of production l Rep Date of last repair l Build Number of compiling If information is not available e g the assy has no software the message is dis...

Page 30: ...m and warning thresholds to the factory settings After the preset is executed a set up assistent is available for easy putting into ope ration see chapter putting into operation Reset Menu Reset Alarm...

Page 31: ...HCP is auto to be set in manual mode l Network MAC chip address of the Ethernet controllers Menu PPP status Indication of the availability of the PPP connection remote control RS 232 Menu PPP configur...

Page 32: ...nu Date Time The time settings stored in history are derived from this clock Format YYYY MM DD HH MM SS Temperature Menu Temp The temperature in the housing is measured The current value can be querie...

Page 33: ...taff with RF knowledge ATTENTION In case of a technical problem send your IRD 8500 to your next service center for repair NOTE Please go to our service homepage http service hirschmann at to find othe...

Page 34: ...s on the display Nominal operation state LED s l LED f does not light up l LED OUT lights up Menu MPEG processing l DMX state sync ok l Decoder state play Menu Video processing l Output signal On Menu...

Page 35: ...ings Input frequency Input level Symbol rate LNB supply option LNB supply LNB 22kHz option LNB supply Tuner state Restore the factory settings with PRESET and re configure the device LED OUT does not...

Page 36: ...T Changing the battery ATTENTION Danger of electric shocks Disconnect the IRD 8500 from the mains before changing the battery WARNING Improper change of the battery may cause an explosion Replacement...

Page 37: ...the correct polarity of the battery 5 Close the cover 6 Reconnect the device to the mains 7 Carry out a functional check see chapter Maintenance IRD 8500 4 6 Intergrated Receiver Decoder 1 Lithium Ba...

Page 38: ...truction enclosed l Close the cover l Reconnect the IRD 8500 to the mains l The option is automatically detected by the software Perform the necessary settings in the menus e g change MPEG input to TS...

Page 39: ...password please contact service rw hirschmann at The password is changed monthly Ordering description Software SW CPU IRD 8500 Ordering number 879 310 814 Ordering description Software SW IRD 8500 Or...

Page 40: ...Order number MPEG interface AS MPI 8505 888 224 001 LNB supply AS LNB 8500 75 888 076 001 Software Description Type Order number Conditional Access Control CAC 8000 879 310 809 Network Access Control...

Page 41: ...fr F 95200 SARCELLES Richard Hirschmann Tel 44 0 1234 34 5999 Electronics UK Ltd FAX 44 0 1234 35 2222 St Martins Way Email richardhirschmann St Martins Business Centre compuserve com GB BEDFORD MK42...

Page 42: ...input F socket VIDEO output 3 x BNC socket AUDIO output Audio socket type XLR 3 poles AUDIO monitoring output 6 3mm jack socket Technical data Power supply Mains voltage 115 V version 97 132 VAC 230 V...

Page 43: ...ontrol signal f 20 24 kHz Zi 15 Ohm Upp 500 800 mV Synchronous Parallel Interface input SPI e Low Voltage Differential Signal Datarate 2 64 Mbit s Clock frequency 250 kHz 8 MHz Frame length 188 or 204...

Page 44: ...al Interface output ASI a Frame length 188 Bytes or 204 Bytes Data rate 270 Mbit s Impedance 75 Ohm Return loss 17 dB 5 270 MHz Level 720 880 mV Monitoring outputs Video monitoring output front panel...

Page 45: ...10 BASE T Pin assignment see Putting into operation Interfaces MPEG interface option Data are delivered with the option Remote monitoring interface ALARMS Max switched voltage 30 VDC oder 42 VAC SELV...

Page 46: ...excluded all net work errors from the list for which local repair does not seem to be feasible Most network errors will cause the device to perform a reset If the network error ho wever persists conta...

Page 47: ...Message Communication problem Cause Unknown Solution Interrupt the power supply for a few seconds OR Restore the factory settings in the SETUP menu and reconfigure the device Message Current overload...

Page 48: ...one of our service centers Message Factory adjustment incomplete Cause The factory settings could not be restored Solution Change the device and contact one of our service centers Message Fatal Could...

Page 49: ...and contact one of our service centers Message I2C bus blocked Cause Communication problem Solution Switch off the installation and interrupt the power supply for a few seconds OR Restore the factory...

Page 50: ...of our service centers Message Power supply failure Cause Unknown Solution Change the device and contact one of our service centers Message QAM failure Cause The problem may result from the fact that...

Page 51: ...re failure Solution Verify that the ambient temperature of the equipment is in the operation range of 0 45 degrees Celsius OR Change the device Message Too many guests online disconnect Cause More tha...