background image

 

SENS-O-MATIC II™ 

Hopper Switch 

 

HIRED-HAND, INC.  

 1733 County Road 68  

 Bremen, AL 35033 USA  

 Phone 256-287-1000  

 Fax 256-287-2000 

Manual Part No. 4802-0134  rev 5-07          Page 

1

 of 2

 

  WARNING!

 

Only qualified electrician personnel familiar with the 

construction and operation of this equipment and the 

hazards involved should install and/or service this 

equipment.  It is important that all standard electrical 

codes be observed when wiring the Sens-O-Matic™. 

Read and understand all instructions and diagrams 

before proceeding.  Failure to observe this precaution 

could result in equipment damage, severe bodily 

injury, or loss of life. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DESCRIPTION 

The Hired Hand Sens-O-Matic II™ is an electronic 
feed hopper switch which turns the feed auger On or 
OFF depending on the hopper feed level.  A 

NEW 

FEATURE

 recently added is the 

Push-to-Reset 

Circuit Breaker

.  The circuit breaker is externally 

accessible and has replaced the internal glass tube 
fuse which required opening the enclosure.  The Sens-
O-Matic™ is a direct retrofit for the standard Paddle 
Switch currently used in the poultry industry.  If the 
feed fill system and paddle-type Hopper Switch is 
controlled by 240vac, a 240vac Sens-O-Matic™ is 
required.  If the feed fill system and paddle-type 
Hopper Switch is controlled by 120vac, a 120vac 
Sens-O-Matic™ is required.  Installation of the Sens-
O-Matic™ is quick and simple with only three wire 
connections as shown in the wiring diagram provided 
on Page 2.  Approximately 3 feet of electrical cord and 
a slide-in mounting tab bracket are supplied 
preattached to the Sens-O-Matic™.  No assembly is 
required.  The Sens-O-Matic™ is preset for an 
approximate 30 second time-delay from an Off state to 
an activated On state when nothing is sensed near the 
sensing area. 
When the kit is received, check for shipping damage. 
Contact Hired-Hand Customer Support for information 
regarding the universal mounting bracket and external 
power supply options if these options are required. 

 

Part # 

Description 

 

6606-0110 

SM-2-I-126S Sens-O-Matic™ 120v 60hz 

 

6606-0114 

SM-2-I-246S Sens-O-Matic™ 240v 60hz 

 

6406-1126 

/Universal Mount Bracket Assembly 

6606-0112 

SM-2-E-246S Sens-O-Matic™ 240v 60hz Ext Pwr Supply 

6607-1598 

PS-24VAC-250VA-120/240VAC Power Supply 

 

 

 

Wire Stripper 

Wire Connectors 

 

Sens-O-Matic II™ 

Assembly & Installation 

 
 
 
 
 
 
 
 
A.  Disconnect AC electrical power from all equipment. 

B.  Place the Sens-O-Matic™ inside the feed hopper 

and slide the mounting tab into the hopper retaining 
slot. 

NOTE

:  The feed tube should not be placed to allow the 

feed to dump directly onto the Sens-O-Matic™. 

C.  Route and secure the Sens-O-Matic™ power cord in 

a safe and secure location. 

D.  Connect the black, white, and green wires as shown 

in the wiring diagram on 

Page 2

E.  Ensure that all wires are secure and safely clear 

from moving/turning auger components. 

F.  Apply power and test the Sens-O-Matic™ with feed 

to ensure proper operation. 

 

 

 

 

 

 

 

 

 

WARNING!

 

  Remove ALL Electrical Power from the feed fill 

system before installation / wiring. 

  Never plug the Sens-O-Matic™ into a standard 120 

or 240 VAC receptacle as serious injury may result. 

Figure 1:  Sens-O-Matic II™ Control 

Mounting Tab 

PCB168 

15 Amp 

Push-to-Reset 

Circuit Breaker 

NEW 

Power 
Connection 

* Patent Number:  5,051,671

Reviews: