background image

 

Light Control Relay Assembly 

For EV-1200, EV-3000, & EV-3001 Controls 

 

HIRED-HAND, INC.  

 1733 County Road 68  

 Bremen, AL 35033 USA  

 Phone 256-287-1000  

 Fax 256-287-2000 

Manual Part No. 4802-5109  rev 2-07          Page 

1

 of 6

 

  WARNING!

 

Only qualified electrician personnel familiar with the 

construction and operation of this equipment and the 

hazards involved should install and/or service this 

equipment.  Read and understand all instructions 

and diagrams before proceeding.  Failure to observe 

this precaution could result in equipment damage, 

severe bodily injury, or loss of life. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DESCRIPTION 

The assembly described in this manual is used for 
converting the EV-1200, EV-3000, or EV-3001 
Variable Module connections into On/Off light control 
contacts in cases when all other stages are being used 
or will be used for other purposes.  This assembly 
provides a quick and simple relay assembly for 
connecting to existing or new EV controllers.  The 
Light Control Relay Assembly includes the relay, one 
prestripped red wire and one prestripped black wire to 
connect to the Variable Module terminal block, and two 
unterminated crimp terminals for connecting customer 
supplied wires to the two normally open relay 
terminals. 
When the kit is received, check for shipping damage. 

 
 
 
 
 
 
 
 
 
 
 

 

Part # 

Description 

Qty 

1903-4044 

HRNS EV1200 Light Contrl Relay 

 

 

Small flat-head screwdriver

 

Crimping Tool

 

Wire Stripper 

 

Section 1.0

 - Light Control Relay Assembly Installation. 

Section 2.0

 - EV-1200 wiring diagrams.

 

Section 3.0

 - EV-3000/3001 wiring diagrams. 

Section 4.0

 -

 

EV-1200, EV-3000, or EV-3001 

programming requirements. 

1.0  Light Control Relay 

Assembly Installation 

 
 
 
 
 
 
 
A.  Disconnect AC electrical power from all equipment. 

B.  Remove the 4-position black terminal block (Variable 

Module) from the circuit board (EV-1200 PCB186 
or EV-3000/3001 PCB169). 

C.  Connect the red wire to the ‘+’ and the black wire to 

the ‘-‘ of either the VAR #1 side or the VAR #2 
side.  Tighten securely. 

D.  Place the 4-position terminal block back onto the 

PCB Variable Module connection. 

E.  Remove the adhesive strip backing from the back 

side of the Relay and place the relay 
approximately midway between the enclosure 
cover and PCB to allow access and removal of the 
other terminal blocks 

F.  Ensure that all wires are clear from hole drilling 

locations. 

G. Refer 

to 

Section 2.0

 or 

Section 3.0

 for the wire 

connections diagram from the Evolution controller 
PCB to the Light Control Relay Assembly. 

NOTE

:  All Stage Inputs must be jumpered as shown in 

Section 2.0 or Section 3.0

 wiring diagram. 

H. Refer 

to 

Section 4.0

 for Program Requirements. 

 

WARNING!

 

Ensure that ALL Electrical Power Sources are 

OFF during installation / wiring. 

Figure 1:  Light Control Relay Installed inside 

EV-1200 Controller 

Light Control Relay 

Variable Module 

Contacts 

Connector 

PCB168 

PCB186 

Crimp Terminals 

Reviews: