background image

 

    

HIOTH

                                          User Manual

 

HIOTH TECHNOLOGY CO.,LTD. 

PM2.5 Monitor 

 

 

Introduction 

PM2.5 Monitor is an air quality controller which compatible with Z-Wave technology, it is mainly 

used to monitor PM2.5 concentration in industrial, agricultural, and residence environment, while 

monitoring  the  indoor  temperature  and  humidity.  Device  can  be  included  into  any  Z-Wave  net-

work, and is compatible with any other Z-Wave certified devices. 

Technical Information 

 

Compatible with any Z-Wave network controller 

 

Monitor PM2.5, temperature and humidity   

 

High accuracy , good real-time performance and low cost 

CT-EDZW4001-MH 

PM2.5 Monitor

 

Summary of Contents for CT-EDZW4001-MH

Page 1: ... in industrial agricultural and residence environment while monitoring the indoor temperature and humidity Device can be included into any Z Wave net work and is compatible with any other Z Wave certified devices Technical Information Compatible with any Z Wave network controller Monitor PM2 5 temperature and humidity High accuracy good real time performance and low cost CT EDZW4001 MH PM2 5 Monit...

Page 2: ...allation Instructions Device is suggested to be installed indoor a place with around 1 5m height above the floor where represents the average PM2 5 concentration It should be away from direct sunlight any cover or any heat source to avoid false signal for detection Notice 1 Device must be wall mounted vertically Do not lay it flat or upside down while working 2 Do not mounted it in a wind gap or c...

Page 3: ...ice and mount the bottom case onto wall with two screws M4 25mm The hole pitch 60mm is for 86 60mm box and 82mm is for American120mm box 3 Mount the panel back by aligning its tabs and card slot onto the bottom case 4 Tighten the fastening screw and the device is ready for normal work Fig 2 Operation Button Display is below ...

Page 4: ...mal display Backlight The backlight will be full bright when any keys pressed and turn to half bright if no operation in10 Sec Including of Z Wave network If device has not been included into any Z Wave network before will display on the screen 1 Connect the power supply and make sure that device in a state of No node ID 2 Long press S1 S3 until displays on the screen 3 Then press S1 once flashing...

Page 5: ...cess will display on the screen please go to the device list interface and refresh the device list the device will not be displayed 6 If the device can still be displayed network exclusion failed repeat steps 2 5 If the device is online directly perform steps 1 6 if the device is offline need interruption of the device power supply first and then perform step 1 6 Note If display flashing long pres...

Page 6: ...tion please confirm the real voltage complying with the device s specification Cut off any power supply to secure the safety of people and device During installation protect the device from any physical damage by dropping or bumping If happened please contact the supplier for maintenance Keep the device away from acid base and other corrosive solids liquids gases to avoid damage Avoid overexertion...

Reviews: