Time Chart
■
Finish Output (Relay contact)
On/OFF Time: 20 ms or less / 20 ms or less
Terminal
Contact resistance
100mΩ or less
Max.current
2A 125V AC
1A 250V AC
(1A 30V DC)
Driver start signal
Driver running
Torque up signal
Finish signal*
*Finish signal is not output during reverse-rotaion.
●
When the screwdriver “Torque up” then the screwdriver stop turning.
“Finish signal” is active after “Torque up” of screwdriver until “Lever Off” of screwdriver.
No “Finish signal” for Reversing.
■
China RoHS2 Table
If you export to China by yourselves, below is the table of China RoHS2.
* In addition, if the following mark cannot be found at the rear side of the
product and/or Product box, cut off a mark and stick a mark to the product
and/or product box.
Note: minimum size of China RoHS mark is 5mm at outer diameter