Switching between Sinking Current (NPN) and Sourcing Current (PNP)
7.2 Switching between Sinking Current (NPN) and
Sourcing Current (PNP)
Thoroughly read “Before starting the external control” (p. 6) beforehand.
The applicable PLC type can be changed using the
EXT. I/O MODE
change-over switch. It is set to
NPN at the time of shipment.
EXT. I/O MODE change-over switch settings
NPN
PNP
Device input circuit
Supports sinking output.
Supports sourcing output.
Device output circuit
Non-polar
Non-polar
ISO_5 V output
+5 V output
-
5 V output
Rear
Left: Sinking current (NPN)
Right: Sourcing current (PNP)