75
7
Specifications
For more information about RM9003 Press Unit, RM9004 Test Fixture, and RM9005 Connection Cord
specifications, please see those products’ respective instruction manuals.
7.1 RM2611 Electrode Resistance Meter
General specifications
Operating environment
Indoors, Pollution Degree 2, altitude of up to 2000 m (6562 ft.)
Operating temperature and humidity
0°C to 40°C (32°F to 104°F), 80% RH or less (no condensation)
Storage temperature and humidity
0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation)
Standards
Safety EN61010
EMC
EN61326 Class A
Power supply
Commercial power
Rated supply voltage: 100 V to 240 V AC (designed to accommodate
voltage fluctuations of ±10% relative to the rated supply voltage)
Rated supply frequency: 50 Hz, 60 Hz
Anticipated transient overvoltage: 2500 V
Maximum rated power: 40 VA (not including PC power)
Interfaces
•
USB port (for connecting the instrument to a PC)
•
Test fixture connector
•
TEMP.SENSOR terminal (for connecting the instrument to the Z2001
Temperature Sensor)
Dimensions
Approx. 215W × 80H × 306.5D mm (8.46″W × 3.15″H × 12.07″D)
Mass
Approx. 3.4 kg (119.9 oz.)
Product warranty period
3 years
Fuse
F1.6AH 250 V ×1
Accessories
Options
Input, output, and measurement specifications
Basic specifications
Measured parameters
DC resistance and temperature
Automatic measurement is performed via the RM2612 Resistance
Calculation Software. Measurement cannot be performed using the
RM2611 Electrode Resistance Meter alone.
Resistance measurement signal
Constant current
Resistance measurement method
DC 4-terminal method
Resistance measurement terminal
Test fixture connector
Resistance measurement range
Ranges: 1000 m
Ω
, 10
Ω
, 100
Ω
, 1000
Ω
, 10 k
Ω
, 100 k
Ω
, 1000 k
Ω
For more information about range parameters, see “Table 1. RM2611
Electrode Resistance Meter Measurement Ranges” (p. 76).
7 Specifications
10
9
8
7
6
5
4
3
2
1
索引
7
Specifications
Summary of Contents for RM2610
Page 2: ......
Page 12: ...8 Operating Precautions...
Page 22: ...18 USB License Key and Screens RM2612 Resistance Calculation Software...
Page 54: ...50 Checking Measurement Results...
Page 72: ...68 Setting Administrator Mode...
Page 110: ...106 Under what circumstances do contact errors occur...
Page 128: ...124 Dimensional Drawings 10 2 Dimensional Drawings RM2611 Electrode Resistance Meter Unit mm...
Page 130: ...126 Dimensional Drawings RM9005 Connection Cable Unit mm...
Page 134: ...130 Index...
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......