background image

PW9100-03
PW9100-04

Warranty

Warranty malfunctions occurring under conditions of normal use in 
conformity with the Instruction Manual and Product Precautionary 
Markings will be repaired free of charge. This warranty is valid for 
a period of one (1) year from the date of purchase.  Please contact 
the distributor from which you purchased the product for further 
information on warranty provisions.

Introduction

Thank you for purchasing the Hioki PW9100-03, PW9100-04 AC/
DC Current Box. To obtain maximum performance from the device, 

please read this manual first, and keep it handy for future reference.

Verifying package contents

When you receive the device, inspect it carefully to ensure that 
no damage occurred during shipping. In particular, check the 
accessories and connectors. If damage is evident, or if it fails to 

operate according to the specifications, contact your authorized 

Hioki distributor or reseller.

Cleaning

To clean the device, wipe it gently with a soft cloth moistened with 
water or mild detergent.

Calibrations

The calibration period varies depending on the status of the device 
or installation environment. We recommend that the calibration 
period be determined in accordance with the status of the device 
or installation environment. Please contact your Hioki distributor to 
have your device periodically calibrated.

Troubleshooting

If the device seems to be malfunctioning, contact your authorized 

Hioki distributor or reseller.When sending the device for repair, be 
sure to include details of the problem.

Discarding the device

Handle and dispose of the device in accordance with local 
regulations.

Overview

This device measures AC and DC currents of up to 50 A with a high 
degree of precision. Thanks to its excellent frequency characteristics 
(amplitude and phase) and temperature characteristics (sensitivity 
and offset), it can be used not only for current measurement, but 
also for high-precision power measurement.

Names of Parts

Output cables

CH A

CH B

CH C

CH D

Front panel

Current input terminals

GND

Safety cover

Affix channel number 

sticker here.

CH D

CH C

CH B

CH A

Rear panel

The above figure depicts the PW9100-04 (4-channel model). 

Safety Information

This device is designed to conform to IEC 61010 Safety Standards, 
and has been thoroughly tested for safety prior to shipment. 
However, using the device in a way not described in this manual 
may negate the provided safety features.
Before using the device, be certain to carefully read the following 
safety notes:

 DANGER

Mishandling during use could result in injury 
or death, as well as damage to the device. Be 
certain that you understand the instructions and 
precautions in the manual before use.

AC/DC CURRENT BOX

Instruction Manual

Dec. 2015

  

Edition 1

Printed in Japan

PW9100A961-00  15-12H

EN

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for PW9100-03

Page 1: ...librated Troubleshooting If the device seems to be malfunctioning contact your authorized Hioki distributor or reseller When sending the device for repair be sure to include details of the problem Discarding the device Handle and dispose of the device in accordance with local regulations Overview This device measures AC and DC currents of up to 50 A with a high degree of precision Thanks to its ex...

Page 2: ...s or specifications Doing so may damage the device or cause it to become hot resulting in bodily injury electric shock To avoid electric shock do not remove the device s case This device should only be connected to the secondary side of a breaker If a short circuit occurs in the secondary side the breaker will interrupt the circuit to prevent a short circuit current from flowing through the second...

Page 3: ...Line A Line B Line C Measurement cables Front Rear Power meter rear of PW6001 1 Power off Power on 2 3 6 7 4 5 8 Crimp contacts Width 17 mm or less Must accept M6 screw Insulated type Tightening torque 2 5 to 3 N m Example current measurement connection 3P3W3M 10 9 Example connections when using 6 channels PW9100 03 PW9100 03 Rear of PW6001 Choosing the connection method Example When using the dev...

Page 4: ...z 0 02 rdg 0 005 f s 0 1 deg 65 Hz f 500 Hz 0 1 rdg 0 01 f s 0 12 deg 500 Hz f 1 kHz 0 1 rdg 0 01 f s 0 5 deg 1 kHz f 5 kHz 0 5 rdg 0 02 f s 0 5 deg 5 kHz f 20 kHz 1 rdg 0 02 f s 1 deg 20 kHz f 50 kHz 1 rdg 0 02 f s 0 05 f deg 50 kHz f 100 kHz 2 rdg 0 05 f s 0 06 f deg 100 kHz f 300 kHz 5 rdg 0 05 f s 0 06 f deg 300 kHz f 700 kHz 5 rdg 0 05 f s 0 07 f deg 700 kHz f 1 MHz 10 rdg 0 05 f s 0 07 f deg...