Select and Query Low Pulse Filter (LPF)
Syntax
Command
:LPF[CH] <OFF/500Hz/5kHz/100kHz>
Query
:LPF[CH]?
[CH]
・・・・
1,2,3,4
Response
<OFF/500Hz/5kHz/100kHz>
Description
Command
Sets the cutoff frequency for the low pulse filter (LPF).
Query
Returns the setting for the cut off frequency for the low pulse filter as a
character string.
Example
Command
:LPF1 500Hz
Set the cutoff frequency for the low pulse filter of Channel 1 to 500Hz.
Query
:LPF1?
Response
:LPF1 500Hz (WHEN HEADER IS ON)
500Hz (WHEN HEADER IS OFF)
Note
By combining measurement lines (for above IP3W), the settings for the low pulse filters (LPF)
of other channels which are combined are also changed.