![Hioki PW3336-01 Instruction Manual Download Page 68](http://html1.mh-extra.com/html/hioki/pw3336-01/pw3336-01_instruction-manual_2137351068.webp)
3.3 Integration
62
The instrument performs integration for the current and active power in the positive direction (Ah+, Wh+), in the
negative direction (Ah-, Wh-), and as sums (Ah, Wh) simultaneously for all channels and can display the inte-
grated value for each. Integration can be started and stopped, and the integrated value can be reset, using either
the instrument’s keys or the external control function. Additionally, by setting the integration time, it is possible to
perform timer integration in 1-minute units from 1 minute to 10,000 hours (approximately 417 days). Further-
more, it is also possible to measure the time average current and time average active power as calculated from
the integrated value at that point in time and the integration elapsed time while integration is being performed.
The effective measurement range for integration is the effective measurement range for current or active
power, and values up to the maximum effective peak voltage or maximum effective peak current (until the
PEAK OVER U
or
PEAK OVER I
lamp lights up) are integrated as valid data.
Maximum effective peak voltage: ±600% of the voltage range (up to ±1,500 Vpeak for the 300 V, 600 V,
and 1,000 V ranges)
Maximum effective peak current: ±600% of the current range (up to ±100 Apeak for the 20 A and 50 A ranges)
Example: When performing DC current integration using the 1 A range, the current display value (A) will change
to [
o.r
] when 1.4 A is exceeded, but the effective measurement range for current integration (Ah)
extends from ±10 mA (1% of the 1 A range) to ±6 A, so the values will be integrated as valid data.
Display parameters and descriptions related to integration
Displaying the rectifier and integrated values
Internally, the following integrated values are all integrated simultaneously, regardless of the rectifier. Conse-
quently, integrated value data with simultaneity can be obtained simply by switching the display parameter.
3.3
Integration
Display parameter
Description
Ah +
Positive current integrated value
Ah -
Negative current integrated value
Ah
Sum of current integrated values
Wh +
Positive active power integrated value
Wh -
Negative active power integrated value
Wh
Sum of active power integrated values
TIME
Integration elapsed time
T.AV A
Time average current (obtained by dividing the sum of current integrated values by the integration elapsed time)
T.AV W
Time average active power (obtained by dividing the sum of active power integrated values by the integra-
tion elapsed time)
Current (Ah+, Ah-, Ah)
Rectifier
Integration operation and display
AC+DC
AC+DC Umn
The results of integrating current RMS value data (display values) once every display update interval (200
ms) are displayed as integrated values.
DC
The results of integrating sampled instantaneous data separately by polarity are displayed as integrated values.
AC
FND
[
- - - - -
] (no integrated data) is shown.
Active power (Wh +, Wh -, Wh)
Rectifier
Integration operation and display
AC+DC
AC+DC Umn
The results of integrating active power values calculated once for every cycle of the selected synchroniza-
tion source separately by polarity are displayed as integrated values. This rectifier is used to integrate ac-
tive power values of cyclic waveforms.
DC
The results of integrating sampled instantaneous data separately by polarity are displayed as integrated
values. This rectifier is used to integrate active power values of non-cyclic waveforms such as a DC or oth-
ers. (When a waveform to be measured includes both a DC and an AC component, the integrated value
will not be an integration of only a DC component.)
AC
FND
[
- - - - -
] (no integrated data) is shown.
Summary of Contents for PW3336-01
Page 2: ......
Page 6: ...Contents iv...
Page 16: ...Operating Precautions 10...
Page 32: ...1 4 Measurement Workflow 26...
Page 44: ...2 7 Turning Off the Instrument 38...
Page 181: ...5 6 Wiring Specifications 175 5 3 phase 4 wire 3P4W Current sensor...
Page 182: ...5 6 Wiring Specifications 176...
Page 199: ...Appendix 4 Dimensional Diagram A13 e g PW3337 03 Appendix 4 Dimensional Diagram Unit mm...
Page 200: ...Appendix 4 Dimensional Diagram A14...
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......